首页> 外文OA文献 >Influence of screw augmentation in posterior dynamic and rigid stabilization systems in osteoporotic lumbar vertebrae: a biomechanical cadaveric study.
【2h】

Influence of screw augmentation in posterior dynamic and rigid stabilization systems in osteoporotic lumbar vertebrae: a biomechanical cadaveric study.

机译:螺钉增强对骨质疏松性腰椎后动态和刚性稳定系统的影响:生物力学尸体研究。

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

STUDY DESIGNududBiomechanical cadaveric study.ududOBJECTIVEududTo determine whether augmentation positively influence screw stability or not.ududSUMMARY OF BACKGROUND DATAududImplantation of pedicle screws is a common procedure in spine surgery to provide an anchorage of posterior internal fixation into vertebrae. Screw performance is highly correlated to bone quality. Therefore, polymeric cement is often injected through specifically designed perforated pedicle screws into osteoporotic bone to potentially enhance screw stability.ududMETHODSududCaudocephalic dynamic loading was applied as quasi-physiological alternative to classical pull-out tests on 16 screws implanted in osteoporotic lumbar vertebrae and 20 screws in nonosteoporotic specimen. Load was applied using 2 different configurations simulating standard and dynamic posterior stabilization devices. Screw performance was quantified by measurement of screwhead displacement during the loading cycles. To reduce the impact of bone quality and morphology, screw performance was compared for each vertebra and averaged afterward.ududRESULTSududAll screws (with or without cement) implanted in osteoporotic vertebrae showed lower performances than the ones implanted into nonosteoporotic specimen. Augmentation was negligible for screws implanted into nonosteoporotic specimen, whereas in osteoporotic vertebrae pedicle screw stability was significantly increased. For dynamic posterior stabilization system an increase of screwhead displacement was observed in comparison with standard fixation devices in both setups.ududCONCLUSIONududAugmentation enhances screw performance in patients with poor bone stock, whereas no difference is observed for patients without osteoporosis. Furthermore, dynamic stabilization systems have the possibility to fail when implanted in osteoporotic bone.
机译:研究设计 ud ud生物力学尸体研究。 ud udOBJECTIVE ud ud确定是否增强对骨钉的稳定性有积极影响。 ud ud背景资料摘要 ud ud椎弓根螺钉的植入是脊柱外科手术中的常见方法后部内固定物固定在椎骨上。螺钉的性能与骨骼质量高度相关。因此,通常通过专门设计的带孔椎弓根螺钉将聚合物胶粘剂注入骨质疏松性骨中,以潜在地增强螺钉的稳定性。 ud udMETHODS ud ud使用头颅动态载荷作为经典拔出试验的准生理替代方法,用于对植入的16颗螺钉进行固定非骨质疏松标本中的骨质疏松性腰椎和20个螺钉。使用模拟标准和动态后稳定装置的2种不同配置施加载荷。通过在加载周期中测量螺丝头的位移来量化螺丝性能。为了减少对骨骼质量和形态的影响,比较了每个椎骨的螺钉性能,然后取平均值。 。对于植入非骨质疏松标本中的螺钉,增幅可忽略不计,而在骨质疏松椎弓根中,螺钉的稳定性显着提高。对于动态后路稳定系统,在这两种设置中,与标准固定装置相比,观察到螺钉头位移都增加。此外,动态稳定系统在植入骨质疏松性骨中时可能会失效。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号