首页> 外文期刊>International Dairy Journal >High-pressure homogenisation of raw bovine milk. Effects on fat globule size distribution and microbial inactivation
【24h】

High-pressure homogenisation of raw bovine milk. Effects on fat globule size distribution and microbial inactivation

机译:原料牛乳的高压均质化。对脂肪球大小分布和微生物失活的影响

获取原文
获取原文并翻译 | 示例
       

摘要

Whole raw milk was processed using a 15 L h(-1) homogeniser with a high-pressure (HP) valve immediately followed by a cooling heat exchanger. The influence of homogenisation pressure (100-300 MPa) and milk inlet temperature T-in (4degreesC, 14degreesC or 24degreesC) on milk temperature T, at the HP valve outlet, on fat globule size distribution and on the reduction of the endogenous flora were investigated. The T-in values of 4-24degreesC led to milk temperatures of 14-33degreesC before the HP valve, mainly because of compression heating. High T-in and/or homogenisation pressure decreased the fat globule size. At 200 MPa, the d(4.3) diameter of fat globules decreased from 3.8 +/- 0.2 (control milk) to 0.80 +/- 0.08 mum, 0.65 +/- 0.10 or 0.37 +/- 0.07 mum at T-in = 4, 14degreesC or 24degreesC, respectively. A second homogenisation pass at 200 MPa (T-in = 4degreesC, 14degreesC or 24degreesC) further decreased d(4.3) diameters to about 0.2 mum and narrowed the size distribution. At all T tested, an homogenisation pressure of 300 MPa induced clusters of fat globules, easily dissociated with SDS, and probably formed by sharing protein constituents adsorbed at the fat globule surface. The total endogenous flora of raw milk was reduced by more than I log cycle, provided homogenisation pressure was greater than or equal to 200 MPa at T-in = 24degreesC (T(2)similar to60degreesC) 250 MPa at T-in = 14degreesC (T(2)similar to62degreesC), or 300 MPa at T-in = 4degreesC (T(2)similar to65degreesC). At all T-in tested, a second pass through the HP valve (200 MPa) doubled the inactivation ratio of the total flora. Microbial patterns of raw milk were also affected; Gram-negative bacteria were less resistant than Gram-positive bacteria.
机译:立即使用带有高压(HP)阀的15 L h(-1)均质机处理全脂原奶,然后立即进行冷却热交换器。均质压力(100-300 MPa)和牛奶入口温度T-in(4°C,14°C或24°C)对HP阀门出口处的牛奶温度T,脂肪球大小分布和内源菌群减少的影响调查。 T值在4-24摄氏度之间,导致高压阀之前的牛奶温度为14-33摄氏度,这主要是因为压缩加热。高T-in和/或均质压力降低了脂肪小球的大小。在200 MPa下,在T-in = 4时,脂肪小球的d(4.3)直径从3.8 +/- 0.2(对照乳)降至0.80 +/- 0.08微米,0.65 +/- 0.10或0.37 +/- 0.07微米,14摄氏度或24摄氏度。在200 MPa(T-in = 4℃,14℃或24℃​​)下第二次均质化处理进一步将d(4.3)直径减小到约0.2微米,并缩小了尺寸分布。在所有测试的T下,均质压力为300 MPa时会诱发脂肪球簇,容易与SDS分离,并且很可能是通过共享吸附在脂肪球表面的蛋白质成分而形成的。如果均质压力在T-in = 24摄氏度(T(2)类似于60摄氏度)时均质压力大于或等于200 MPa,则在T-in = 14摄氏度(250 MPa)时,生乳的总内源菌群减少幅度将超过对数周期T(2)接近62摄氏度),或在T-in = 4摄氏度(T(2)接近65摄氏度)时为300 MPa。在所有T-in测试中,第二次通过高压阀(200 MPa)使总菌群的失活率增加了一倍。生乳的微生物模式也受到影响;革兰氏阴性细菌的抵抗力低于革兰氏阳性细菌。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号