Quantitative Analysis of the Immunosuppressant CP-690,550 in Whole Blood by Column-Switching High-Performance Liquid Chromatography and Mass Spectrometry Detection.

机译:通过柱切换高效液相色谱和质谱检测对全血中的免疫抑制剂CP-690,550进行定量分析。

获取原文
获取原文并翻译 | 示例
           

摘要

A fast and accurate method to quantify the new immunosuppressive JAK3 inhibitor CP-690,550 in whole blood using a dual-pump liquid chromatography-liquid chromatography-mass spectrometry (LC/LC-MS) system was developed and validated in nonhuman primate blood. Before injection, blood samples were prepared by precipitation with a reagent that included methanol and acetonitrile (30:70, vol/vol) along with the internal standard (CP-istd). Column-switching LC/LC-MS analysis used online extraction followed by separation on a C8 analytic column and MS detection of the [M + H] CP-690,550 (m/z = 313.1) and CP internal standard (m/z = 288.1). Linearity was always better than r = 0.99 (n = 7) for CP-690,550 (range 2.5-750 ng/mL), with a lower limit of quantification (LLOQ) of 2.5 ng/mL. The intrarun accuracy and precision ranged from 103.0% to 105.4% and 2.7% to 4.3%, respectively (n = 5), and the interday precision ranged from 8.7% to 11.1%, and the interday accuracy ranged from 98.1% to 103.8% of nominal values (n = 14). The injection repeatability for the method was 1.3% (n = 7). Except for the LLOQ, the intraday accuracy and precision in human blood were also within 15% (n = 5). The combination of simple sample preparation and short analytic run time of this sensitive procedure makes it effective for monitoring the concentration of CP-690,550 in whole blood in organ-transplant recipients.
机译:开发了一种快速,准确的方法,使用双泵液相色谱-液相色谱-质谱(LC / LC-MS)系统定量全血中的新型免疫抑制性JAK3抑制剂CP-690,550,并在非人类灵长类动物血液中进行了验证。注射前,通过用包括甲醇和乙腈(30:70,体积/体积)以及内标物(CP-istd)的试剂沉淀来制备血液样品。色谱柱切换LC / LC-MS分析使用在线提取,然后在C8分析柱上分离,并通过MS检测[M + H] CP-690,550(m / z = 313.1)和CP内标(m / z = 288.1) )。对于CP-690,550(范围2.5-750 ng / mL),线性始终优于r = 0.99(n = 7),定量下限(LLOQ)为2.5 ng / mL。批内精度和精度分别为103.0%至105.4%和2.7%至4.3%(n = 5),日间精度为8.7%至11.1%,日间精度为98.1%至103.8%。标称值(n = 14)。该方法的进样重复性为1.3%(n = 7)。除LLOQ外,人类血液中的日内准确性和精确度也在15%以内(n = 5)。这种敏感程序的简单样品制备和短分析时间相结合,使它可以有效地监测器官移植接受者全血中CP-690,550的浓度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号