The haemoglobin (Hb) values of 360 outpatients of a rural hospital in Haryana, India, was determined using the haemocue (HQ) method and the standard blood cell counter (BCC) method. It was found that 3.9 and 2.5% of the subjects had Hb less than 7 g/dl based on the BCC and HQ methods, respectively. The mean Hb values were 10.86 and 12.22 g/dl by the BCC and HQ methods, respectively. The sensitivity and specificity of the HQ method in comparison to the BCC method were 91.7 and 85.2%, respectively. The correlation coefficient was 0.900, indicating good correlation between the 2 methods. The HQ method overestimated Hb levels as compared to the BCC method. However, it was simple to operate and could be used in the field after adjusting for Hb values as provided in the regression equation..
机译:印度的哈里亚纳邦一家乡村医院的360名门诊患者的血红蛋白(Hb)值是使用血液(HQ)方法和标准血细胞计数器(BCC)方法确定的。根据BCC和HQ方法,发现分别有3.9%和2.5%的受试者Hb低于7 g / dl。通过BCC和HQ方法,平均Hb值分别为10.86和12.22 g / dl。与BCC方法相比,HQ方法的灵敏度和特异性分别为91.7%和85.2%。相关系数为0.900,表明这两种方法之间具有良好的相关性。与BCC方法相比,HQ方法高估了Hb水平。但是,它操作简单,并且可以按照回归方程式调整Hb值后在现场使用。