In this paper, we describe the experimental approaches to understand the microdischarge physics of an alternating current plasma display panel (ac PDP) cell. We discuss the experimental techniques to explore the major parameters to understand the operation of ac PDP such as the vacuum ultra violet (VUV) emission and wall charge variation. Regarding the discharge dynamics, the detailed VUV emission characteristics were measured and explained by the gas reaction modeling and the microdischarge characteristics during the ramp reset period were compared with the simulation result. The wall voltage and wall charge distribution were measured by laser induced fluorescence (LIF) and electro-optic modulation method. The slight increase of the wall voltage by Xe addition to pure He discharge gas was observed by LIF. And the existence of self-erasing discharge results in the drastic decrease of wall charge near discharge gap.
机译:在本文中,我们描述了了解交流电等离子体显示面板(ac PDP)电池的微放电物理学的实验方法。我们讨论了实验技术,以探索了解交流PDP操作的主要参数,例如真空紫外(VUV)发射和壁电荷变化。关于放电动力学,通过气体反应模型测量并解释了详细的VUV发射特性,并将斜坡重置期间的微放电特性与仿真结果进行了比较。通过激光诱导荧光(LIF)和电光调制方法测量壁电压和壁电荷分布。通过LIF观察到,通过向纯He放电气体中添加Xe,壁电压略有增加。自擦除放电的存在导致放电间隙附近壁电荷的急剧减少。