首页> 外文期刊>Journal of food protection >Inoculation of Beef with Low Concentrations of Escherichia coli O157:H7 and Examination of Factors That Interfere with Its Detection by Culture Isolation and Rapid Methods
【24h】

Inoculation of Beef with Low Concentrations of Escherichia coli O157:H7 and Examination of Factors That Interfere with Its Detection by Culture Isolation and Rapid Methods

机译:低浓度大肠杆菌O157:H7的牛肉接种以及通过培养分离和快速方法检测干扰牛肉的因素的检查

获取原文
获取原文并翻译 | 示例
       

摘要

Currently used industry testing programs require the ability to detect Escherichia coli O157:H7 in samples of beef trim or ground beef at levels as low as 1 CFU/375 g. We present a reliable protocol for generating a control inoculum for verification testing at this low concentration and evaluate its use. Results show that half of all samples received no cells when 1 CFU was the target concentration and that targets greater than 3 CFU were much more reliable. Detection by culture isolation and two commercial assays, Qualicon BAX-MP and BioControl GDS, detected 94% ± 11%, 92% ± 10%, and 92% ± 7% of samples inoculated with 5.4 CFU (range 1 to 9 CFU), respectively. We also examined the effect of background aerobic plate count (APC) bacteria and fat content effects on the detection of E. coli O157:H7. At APC concentrations below 6 log CFU/g, the rapid methods detected all beef trim samples inoculated with 26 CFU of E. coli O157:H7 per 65 g. At an APC of 6.7 log CFU/g, culture, BAX-MP, and GDS detected 100, 75, and 13%, respectively, of inoculated samples. Neither commercial method detected E. coli O157:H7 in the samples when APC was 7.7 log CFU/g, whereas culture was able to detect 63% of E. coli O157:H7 in the samples when APC was at this concentration. Increased fat content correlated with decreasing recovery of immunomagnetic separation beads, but this was not observed to interfere with detection of E. coli O157:H7.
机译:当前使用的行业测试程序要求能够检测低至1 CFU / 375 g的牛肉条或碎牛肉样品中的大肠杆菌O157:H7。我们提出了一种可靠的协议,用于生成控制接种物以进行这种低浓度的验证测试并评估其用途。结果表明,当目标浓度为1 CFU时,所有样品中的一半都没有细胞,而目标浓度大于3 CFU则更可靠。通过培养物分离和Qualicon BAX-MP和BioControl GDS两种商业化检测进行检测,检测出接种5.4 CFU(范围1至9 CFU)的样品的94%±11%,92%±10%和92%±7%,分别。我们还检查了背景有氧平板计数(APC)细菌和脂肪含量对大肠杆菌O157:H7检测的影响。在APC浓度低于6 log CFU / g时,快速方法检测到每65 g接种了26 CFU大肠杆菌O157:H7的所有牛肉条样品。在6.7 log CFU / g的APC下,培养物,BAX-MP和GDS分别检测到100%,75%和13%的接种样品。当APC为7.7 log CFU / g时,两种商业方法均未检测到样品中的大肠杆菌O157:H7,而当APC处于该浓度时,培养物能够检测出样品中63%的大肠杆菌O157:H7。脂肪含量增加与免疫磁分离珠的回收率降低相关,但是未观察到这会干扰大肠杆菌O157:H7的检测。

著录项

  • 来源
    《Journal of food protection》 |2010年第12期|p.2180-2188|共9页
  • 作者单位

    U.S. Department of Agriculture, Agricultural Research Service, Roman L. Hruska U.S. Meat Animal Research Center, Clay Center, Nebraska 68933-0166;

    U.S. Department of Agriculture, Agricultural Research Service, Roman L. Hruska U.S. Meat Animal Research Center, Clay Center, Nebraska 68933-0166;

    U.S. Department of Agriculture, Agricultural Research Service, Roman L. Hruska U.S. Meat Animal Research Center, Clay Center, Nebraska 68933-0166;

    U.S. Department of Agriculture, Agricultural Research Service, Roman L. Hruska U.S. Meat Animal Research Center, Clay Center, Nebraska 68933-0166;

    U.S. Department of Agriculture, Agricultural Research Service, Roman L. Hruska U.S. Meat Animal Research Center, Clay Center, Nebraska 68933-0166;

    IEH Laboratories & Consulting Group, 15300 Bothell Way N.E., Lake Forest Park, Washington 98155, USA;

  • 收录信息 美国《科学引文索引》(SCI);美国《化学文摘》(CA);