首页> 外文OA文献 >A Comparison of Methods for Assessing Space Suit Joint Ranges of Motion
【2h】

A Comparison of Methods for Assessing Space Suit Joint Ranges of Motion

机译:太空服关节运动范围评估方法的比较

摘要

Through the Advanced Exploration Systems (AES) Program, NASA is attempting to use the vast collection of space suit mobility data from 50 years worth of space suit testing to build predictive analysis tools to aid in early architecture decisions for future missions and exploration programs. However, the design engineers must first understand if and how data generated by different methodologies can be compared directly and used in an essentially interchangeable manner. To address this question, the isolated joint range of motion data from two different test series were compared. Both data sets were generated from participants wearing the Mark III Space Suit Technology Demonstrator (MK-III), Waist Entry I-suit (WEI), and minimal clothing. Additionally the two tests shared a common test subject that allowed for within subject comparisons of the methods that greatly reduced the number of variables in play. The tests varied in their methodologies: the Space Suit Comparative Technologies Evaluation used 2-D photogrammetry to analyze isolated ranges of motion while the Constellation space suit benchmarking and requirements development used 3-D motion capture to evaluate both isolated and functional joint ranges of motion. The isolated data from both test series were compared graphically, as percent differences, and by simple statistical analysis. The results indicated that while the methods generate results that are statistically the same (significance level p= 0.01), the differences are significant enough in the practical sense to make direct comparisons ill advised. The concluding recommendations propose direction for how to bridge the data gaps and address future mobility data collection to allow for backward compatibility.
机译:通过高级探索系统(AES)计划,NASA尝试使用来自50年太空服测试的大量太空服机动性数据来构建预测分析工具,以帮助为将来的任务和探索计划进行早期架构决策。但是,设计工程师必须首先了解是否可以直接比较由不同方法生成的数据以及如何比较这些数据,以及如何以本质上可互换的方式使用它们。为了解决这个问题,比较了来自两个不同测试系列的运动数据的孤立关节范围。这两个数据集均来自穿着Mark III太空服技术演示器(MK-III),腰围I服(WEI)和极简服装的参与者。另外,这两个测试共享一个共同的测试主题,允许在主题之间进行方法的比较,从而大大减少了进行中的变量的数量。测试的方法各不相同:“太空服比较技术评估”使用2-D摄影测量法分析孤立的运动范围,而“星座”太空服基准测试和需求开发使用3-D运动捕获来评估孤立的和功能性关节运动范围。将来自两个测试系列的隔离数据以图形方式进行比较,以百分比差异的形式进行比较,并通过简单的统计分析进行比较。结果表明,尽管这些方法所产生的结果在统计上是相同的(显着性水平p = 0.01),但从实际意义上讲,这些差异足够明显,因此建议不要进行直接比较。结论性建议为如何弥合数据差距和解决未来的移动性数据收集提供了方向,以实现向后兼容性。

著录项

  • 作者

    Aitchison Lindsay T.;

  • 作者单位
  • 年度 2012
  • 总页数
  • 原文格式 PDF
  • 正文语种
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号