首页> 外文期刊>Spine >Cervical sagittal range-of-motion analysis using three methods. Cervical range-of-motion device, 3space, and radiography.
【24h】

Cervical sagittal range-of-motion analysis using three methods. Cervical range-of-motion device, 3space, and radiography.

机译:使用三种方法进行颈矢状位运动范围分析。颈椎活动范围设备,3空间和放射线照相。

获取原文
获取原文并翻译 | 示例
       

摘要

STUDY DESIGN: Cervical flexion, extension, protrusion, and retraction were comparatively measured in volunteers using a cervical range-of-motion device (Performance Attainment Associates, Roseville, MN), a 3space system (Polhemus, Colchester, VT), and lateral radiographs. OBJECTIVES: To compare the outcomes of three methods of measurement of cervical flexion, extension, protrusion, and retraction. SUMMARY OF BACKGROUND DATA: Few studies compare cervical range-of-motion measurement devices with radiographic measurements, and no studies have compared methods of measurement for cervical protrusion and retraction measurement. METHODS: In 20 asymptomatic volunteers, four end-range sagittal cervical positions (flexion, extension, protrusion, and retraction) were measured simultaneously using a cervical range-of-motion device, a 3Space and lateral cervical radiographs. Measurements were compared, and differences were analyzed. RESULTS: There were no significant differences for flexion and extension measurements between the cervical range-of-motion device and that radiographic angle determined by an occipital line and the vertical, nor were there any between the 3Space and that radiographic angle between this same occipital line and C7. The cervical range-of-motion device and the 3Space measurements for flexion and extension, however, differed significantly from one another (P < 0.05). For protrusion and retraction, there was no significant difference between the 3Space and radiographic measurements, but these two both differed significantly from the cervical range-of-motion device (P < 0.05). CONCLUSIONS: Available methods of measurement differ as to whether the cervical spine is isolated or includes upper thoracic motion. Protrusion and retraction can be measured reliably with all three methods studied, but without measurement consistency between devices. Because end-range cervical flexion and extension-cannot occur in isolation from upper thoracic motion, true cervical motion can be measured only withan internally referenced, or landmark-based, methodology such as the 3Space. Even though the cervical range-of-motion device cannot measure isolated cervical flexion and extension, it is nevertheless a reliable clinical tool in measuring flexion and extension as well as protrusion and retraction as long as patient thoracic positioning is standardized to minimize the upper thoracic contribution.
机译:研究设计:使用颈椎运动范围设备(Performance Attainment Associates,罗斯维尔,明尼苏达州),3空间系统(Polhemus,科尔切斯特,佛蒙特州)和侧位X光片对志愿者的颈椎屈曲,伸展,伸出和缩进进行了比较测量。 。目的:比较三种测量颈椎屈曲,伸展,突出和收缩的方法的结果。背景数据摘要:很少有研究将颈椎活动范围测量设备与放射线照相测量相比较,并且没有研究将颈椎前伸和缩回测量的测量方法进行比较。方法:在20名无症状志愿者中,使用子宫颈活动范围仪,3Space和颈椎侧位X光片同时测量了四个终点范围的矢状颈位(屈曲,伸展,伸出和缩回)。比较测量值,并分析差异。结果:子宫颈活动范围装置的屈伸测量与由枕骨线和垂直线确定的射线照相角度之间没有显着差异,在3Space和同一枕骨线之间的射线照相角度之间也没有任何差异和C7。颈椎活动范围设备和3Space的屈伸测量结果彼此之间存在显着差异(P <0.05)。对于前伸和后退,3Space和放射线照相测量值之间没有显着差异,但是这两者与颈椎活动范围装置存在显着差异(P <0.05)。结论:可用的测量方法在颈椎是孤立还是包括上胸运动方面有所不同。可以使用所有研究的三种方法可靠地测量伸出和缩回,但是在设备之间没有测量一致性。由于末端范围的颈椎屈曲和伸展不能独立于上胸廓运动而发生,因此只能使用内部参考的或基于界标的方法(例如3Space)来测量真正的颈椎运动。即使子宫颈活动范围设备无法测量孤立的子宫颈屈曲和伸展,但只要标准化患者胸廓定位以最大程度地减小上胸的贡献,它仍然是测量屈伸,伸出和缩回的可靠临床工具。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号