首页> 外文期刊>Acta orthopaedica. >Hydroxyapatite (HA) coating appears to be of benefit for implant durability of tibial components in primary total knee arthroplasty.
【24h】

Hydroxyapatite (HA) coating appears to be of benefit for implant durability of tibial components in primary total knee arthroplasty.

机译:羟基磷灰石(HA)涂层对于初次全膝关节置换术中胫骨组件的植入物耐久性似乎是有益的。

获取原文
获取原文并翻译 | 示例
           

摘要

BACKGROUND: It is unclear whether there is a clinical benefit to adding hydroxyapatite (HA) coatings to total knee implants, especially with the tibial component, where failure of the implant more often occurs. A systematic review of the literature was undertaken to identify all prospective randomized trials for determining whether the overall clinical results (as a function of durability, function, and adverse events) favored HA-coated tibial components. METHODS: A comprehensive literature search was performed for the years 1990 to September 16, 2010. We restricted our search to randomized controlled trials involving participants receiving either an HA-coated tibia or other forms of tibial fixation. The primary outcome measures evaluated were durability, function, and acute adverse events. RESULTS: Data from 926 evaluable primary total knee implants in 14 studies were analyzed. Using an RSA definition for durability, HA-coated tibial components (porous or press-fit) without screw fixation were less likely to be unstable at 2 years than porous and cemented metal-backed tibial components (RR = 0.58, 95% CI: 0.34-0.98; p = 0.04, I(2) = 39%, M-H random effects model). There was no significant difference in durability, as measured from revision and evaluated at 2 and 8-10 years, between groups. Also, functional status using different validated measures showed no significant difference at 2 and 5 years, no matter what measure was used. Lastly, there was no significant difference in adverse events. Limitations included small numbers of evaluable patients ( 65 years of age, an HA-coated tibial implant may provide better durability than other forms of tibial fixation. Larger trials should be undertaken comparing the long-term durability, function, and adverse events of HA-coated implants with those of other porous-coated tibial implants in younger, more active OA patients.
机译:背景:目前尚不清楚在全膝关节植入物中添加羟基磷灰石(HA)涂层是否具有临床益处,尤其是在胫骨组件中,这种情况下植入物的失败率更高。进行了系统的文献回顾,以鉴定所有前瞻性随机试验,以确定总体临床结果(作为耐久性,功能和不良事件的函数)是否有利于HA涂层胫骨组件。方法:对1990年至2010年9月16日进行了全面的文献搜索。我们将搜索范围局限于接受HA涂层胫骨或其他形式胫骨固定术的参与者的随机对照试验。评估的主要结局指标是持久性,功能和急性不良事件。结果:分析了14项研究中926例可评估的初次全膝关节植入物的数据。使用RSA定义的耐用性,没有螺钉固定的HA涂层胫骨组件(多孔或压入配合)在2年内比多孔的和骨水泥金属支撑的胫骨组件不太可能不稳定(RR = 0.58,95%CI:0.34) -0.98; p = 0.04,I(2)= 39%,MH随机效应模型)。两组之间的经修订和在2年和8-10年评估的耐久性没有显着差异。同样,无论采用哪种措施,使用不同有效措施的功能状态在2年和5年时均无显着差异。最后,不良事件没有显着差异。局限性包括在所确定的14项试验中的7项中可评估的患者人数较少(

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号