A new microfabrication technology for a silicon cantilever array probe card is developed, with technical requirements from Sino IC Technology Co. Ltd for dies under test of 8 inch wafers. A probe card consisting of 96 silicon probes for simultaneously testing two dies is designed and fabricated with bulk micromachining technologies. According to the requirements, a probing force of 25 mN is designed for over-drive displacement no lower than 20 mu m. By using a double- sided metal overlapping scheme, electric feed-through is realized from the probe tips at the bottom to the automatic testing equipment interface on the topside. A recessed concave step is designed and formed to automatically isolate the adjacent probes when a conductive metal layer is sputtered on the surface of the cantilever tips. Characterization of the probe card shows that the resistance at the feed-through via holes is generally lower than 0.8 Omega. In addition, the parasitic capacitance between adjacent probes is as low as 0.02-0.03 pF. The spring constant of the cantilevers is measured as 1126.8 N m-1, which agrees well with the design.
机译:开发了一种新的硅悬臂阵列探针卡的微细加工技术,该技术要求由Sino IC Technology Co. Ltd.进行8英寸晶圆的测试。使用批量微加工技术设计和制造了由96个硅探针组成的探针卡,用于同时测试两个芯片。根据要求,设计了25 mN的探测力,用于不低于20μm的超速驱动位移。通过使用双面金属重叠方案,可实现从底部的探针尖端到顶部的自动测试设备接口的电馈通。设计并形成一个凹入的凹入台阶,以在将导电金属层溅射在悬臂末端的表面上时自动隔离相邻的探针。探针卡的特性表明,穿通孔的电阻通常低于0.8Ω。此外,相邻探针之间的寄生电容低至0.02-0.03 pF。悬臂的弹簧常数测得为1126.8 N m-1,与设计非常吻合。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号