首页> 外文期刊>Mechatronics, IEEE/ASME Transactions on >Spectral Signatures of Pneumatic Actuator Failures: Closed-Loop Approach
【24h】

Spectral Signatures of Pneumatic Actuator Failures: Closed-Loop Approach

机译:气动执行器故障的频谱特征:闭环方法

获取原文
获取原文并翻译 | 示例

摘要

This paper presents a new approach for fault detection and prognosis, using the principle of reduced interference on a probing signal in a closed-loop control system. The method is based on multisinusoidal signals, filter banks, and spectral analysis. A case study is presented to show that it is possible to design and introduce a disturbance into an aircraft pneumatic control loop to measure the degradation of the system components due to different factors including aging. The presented results are based on a validated nonlinear model of an aircraft pneumatic system, and the results indicate that the proposed method can be used to detect and isolate systems failures, estimate the time-to-failure information, and design health management systems.
机译:本文提出了一种新的故障检测和预后方法,它采用了减少闭环控制系统中对探测信号的干扰的原理。该方法基于多正弦信号,滤波器组和频谱分析。案例研究表明,可以设计干扰并将其引入飞机气动控制回路中,以测量由于包括老化在内的各种因素而导致的系统组件的退化。提出的结果基于经过验证的飞机气动系统的非线性模型,结果表明,该方法可用于检测和隔离系统故障,估计故障时间信息以及设计健康管理系统。