首页> 外文期刊>Journal of Food Science >Studies on Disinfection Mechanism of Electrolyzed Oxidizing Water on E. coli and Staphylococcus aureus
【24h】

Studies on Disinfection Mechanism of Electrolyzed Oxidizing Water on E. coli and Staphylococcus aureus

机译:电解氧化水对大肠杆菌和金黄色葡萄球菌消毒机理的研究

获取原文
获取原文并翻译 | 示例
           

摘要

Suspension quantitative germicidal test showed that electrolyzed oxidizing water (EO water) was an efficient and rapid disinfectant. Disinfection rates towards E. coli (available chlorine concentration ACC: 12.40 mg/L) and Staphylococcus aureus (ACC: 37.30 mg/L) could reach 100% at 1 and 3 min, respectively. Disinfection mechanism of EO water was investigated at a molecular biological level by detecting a series of biochemical indices. The results showed that the dehydrogenase activities of E. coli and 5. aureus decreased rapidly, respectively, at the rates of 45.9% and 32% in the 1st minute treatment with EO water. EO water also improved the bacterial membrane permeability, causing the rise of conductivities and the rapid leakages of intracellular DNA, K~+, and proteins in 1 min. The leakages of DNA and K~+ tended to slow down after about 1 min while those of proteins began to decrease a little after reaching the peak values. The sodium dodecyl sulfonate polyacrylamide gel electrophoresis (SDS-PAGE) showed that EO water destroyed intracellular proteins. The protein bands got fainter and even disappeared as the treatment proceeded. EO water's effects on the bacterial ultrastructures were also verified by the transmission electronic microscopy (TEM) photos. The disinfection mechanism of EO water was composed of several comprehensive factors including the destruction of bacterial protective barriers, the increase of membrane permeability, the leakage of cellular inclusions, and the activity decrease of some key enzymes.
机译:悬浮定量杀菌试验表明,电解氧化水(EO水)是一种高效,快速的消毒剂。对大肠杆菌(有效氯浓度ACC:12.40 mg / L)和金黄色葡萄球菌(ACC:37.30 mg / L)的消毒率分别在1分钟和3分钟时达到100%。通过检测一系列生化指标,从分子生物学的角度研究了EO水的消毒机理。结果表明,在EO水处理的第一分钟中,大肠杆菌和金黄色葡萄球菌的脱氢酶活性分别迅速下降,分别为45.9%和32%。 EO水还提高了细菌膜的通透性,在1分钟内引起了电导率的上升以及细胞内DNA,K〜+和蛋白质的快速泄漏。大约1分钟后,DNA和K〜+的渗漏趋于减慢,而蛋白质的渗漏在达到峰值后开始下降。十二烷基磺酸钠聚丙烯酰胺凝胶电泳(SDS-PAGE)表明,EO水破坏了细胞内蛋白。随着治疗的进行,蛋白带逐渐变弱甚至消失。 EO水对细菌超微结构的影响也通过透射电子显微镜(TEM)照片得到了验证。 EO水的消毒机理包括细菌保护屏障的破坏,膜通透性的增加,细胞内含物的泄漏以及某些关键酶的活性下降等综合因素。

著录项

  • 来源
    《Journal of Food Science》 |2010年第5期|P.M253-M260|共8页
  • 作者单位

    School of Life Science and Technology, Tongji Univ., Shanghai, 200092, China;

    rnDept. of Chemistry, Tongji Univ., Shanghai, 200092, China;

    rnSchool of Life Science and Technology, Tongji Univ., Shanghai, 200092, China;

    rnDept. of Chemistry, Tongji Univ., Shanghai, 200092, China;

    rnDept. of Chemistry, Tongji Univ., Shanghai, 200092, China;

    rnDept. of Chemistry, Tongji Univ., Shanghai, 200092, China;

    rnSchool of Life Science and Technology, Tongji Univ., Shanghai, 200092, China;

  • 收录信息 美国《科学引文索引》(SCI);美国《生物学医学文摘》(MEDLINE);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    disinfection mechanism; E. coli; electrolyzed oxidizing water; Staphylococcus aureus;

    机译:消毒机制;大肠杆菌;电解氧化水;金黄色葡萄球菌;