首页> 外文期刊>Scientific reports. >Sanitization Efficacy of Slightly Acidic Electrolyzed Water against pure cultures of Escherichia coli, Salmonella enterica, Typhimurium, Staphylococcus aureus and Bacillus cereus spores, in Comparison with Different Water Hardness
【24h】

Sanitization Efficacy of Slightly Acidic Electrolyzed Water against pure cultures of Escherichia coli, Salmonella enterica, Typhimurium, Staphylococcus aureus and Bacillus cereus spores, in Comparison with Different Water Hardness

机译:与不同的水硬度相比,对大肠杆菌,沙门氏菌肠,毛刺,金黄色葡萄球菌和芽孢杆菌和芽孢杆菌孢子和芽孢杆菌和芽孢杆菌孢子的消毒疗效相比

获取原文
           

摘要

The Influence of water source on the production of slightly acidic electrolyzed water (SAEW) and its sanitization efficacy were investigated. Two different water sources (tap water (TW) and underground water (UGW)) were applied to produce slightly acidic electrolyzed water (SAEW) at same setting current, with similar electrolyte flow rate (EFR) and concentration. Properties of SAEW were evaluated based on pH, Available chlorine concentration (ACC) and oxidation-reduction potential (ORP). Methods for the optimization of SAEW production process was examined to obtain high ACC value by implanting different types of electrolytes. Effect of ACC and pH of SAEW were evaluated in vitro towards inactivate foodborne pathogens. The results indicated that TW with hardness of 29 ppm produced effectively SAEW than through UGW (12 ppm) using electrolytes. Likewise, low water hardness could be reinforced by combining HCL with a salt (NaCl or KCL). The optimized SAEW production system was determined at 4% HCl?+?2.0?M KCL with EFR of 2?mL/min and 4% HCl?+?3.0?M KCL with EFR of 2?mL/min resulting in higher ACC value of 56.5 and 65.5 ppm, respectively using TW. Pathogenic vegetative cells were completely inactivated within 1?min of treatment in SAEW with 20 ppm. Viability observations using Confocal and TEM Microscopy, Flow cytometry, and antimicrobial activity were carried out to confirm the sanitizing effect and cell membrane disruption. Based on the experimental results obtained, it provides a foundation for future advancement towards commercial application of SAEW in the food and agricultural industries.
机译:研究了水源对微酸性电解水(SAEW)的影响及其消毒效能。应用两个不同的水源(自来水(TW)和地下水(UGW))以在相同的设定电流下产生微酸性电解水(SAEW),具有类似的电解质流速(EFR)和浓度。基于pH,可用的氯浓度(ACC)和氧化还原电位(ORP)评估SAEW的性质。研究了萨彻生产过程优化的方法,通过植入不同类型的电解质来获得高ACC值。在体外评估ACC和SAEW的pH的效果朝向灭活食源性病原体。结果表明,使用电解质的UGW(12ppm)产生29ppm的硬度为29ppm的Tw。同样,通过将HCl与盐(NaCl或Kcl)组合来加强低水力。优化的SAEW生产系统以4%HCl + + + +α.2.0≤2.0克/分别测定为2?ml / min和4%HCl +→3.0μmkCl,EFR为2?ml / min,导致较高的ACC值56.5和65.5 ppm,分别使用tw。致病植物细胞在萨夫治疗的1℃内完全灭活,20 ppm。进行使用共聚焦和TEM显微镜,流式细胞术和抗微生物活性的可活力观察,以确认消毒效果和细胞膜破坏。基于获得的实验结果,它为未来进展索维在食品和农业产业中的商业应用方面提供了基础。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号