Background: Coronary artery disease (CAD) is one of the leading cause of the morbidity and mortality in India as well as worldwide and last decade has seen a steep rise in incidence of CAD in India. Direct visualization of the coronary arteries by invasive catheterization still represents the cornerstone of the evaluation of CAD. Cardiac imaging is a challenge of 21st century and is being answered by 128 slice dual source CT as it has good temporal resolution, high scanning speed as well as low radiation dose.Aim: To assess the diagnostic accuracy of 128-slice dual source CT Cardiac Angiography in comparison with Conventional Catheter Cardiac Angiography.Materials and Methods: Forty patients attending the cardiology OPD with complaint of chest pain and suspected of having CAD were evaluated by CT coronary angiography and conventional invasive Catheter coronary angiography and the results were compared. All patients were checked for serum creatinine and ECG before the angiography. Computed Tomography (CT) coronary angiography was done using SIEMENS 128-slice Dual Source Flash Definition CT Scanner under either Retrospective or Prospective mode depending on the heart rate of the patient. Oral/IV beta-blocker were used whenever required.Results: Coronary arteries were assessed as per 17-segment AHA model. A total of 600/ 609 segments were evaluable in 40 suspected patients on CT coronary angiography, of which 21 were false positives and 8 were false negatives with specificity of 95.12% and sensitivity and positive predictive value of 95.26% and 88.46% respectively. Conclusion: Non-invasive assessment of CAD is now possible with high accuracy on 128-slice dual source CT scanner.
机译:背景:冠状动脉疾病(CAD)是印度乃至全世界发病和死亡的主要原因之一,并且在最近十年中,印度的CAD发病率急剧上升。通过侵入性导管插入术直接显示冠状动脉仍然代表着CAD评价的基础。心脏成像是21世纪的一项挑战,它具有良好的时间分辨率,高扫描速度和低辐射剂量,因此得到了128层双源CT的回答。目的:评估128层双源CT心脏的诊断准确性血管造影术与常规导管血管造影术的比较。材料与方法:对40例因胸痛而参加心脏病学OPD并怀疑患有CAD的患者进行了CT冠状动脉造影和常规侵入性导管冠状动脉造影检查,并对结果进行了比较。在血管造影前检查所有患者的血清肌酐和心电图。根据患者的心律,在回顾性或前瞻性模式下,使用SIEMENS 128片双源Flash清晰度CT扫描仪进行计算机断层扫描(CT)冠状动脉造影。结果:根据17段AHA模型评估了冠状动脉。在40例CT冠状动脉造影可疑患者中,共评估600/609个段,其中假阳性21例,假阴性8例,特异性分别为95.12%和99.56%,阳性预测值为88.46%。结论:现在可以在128层双源CT扫描仪上以高精度进行CAD的非侵入性评估。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号