首页> 外文期刊>IEEE Transactions on Applied Superconductivity >Effects of contact resistance between strands with Cron-Cr coating in cable-in-conduit conductors
【24h】

Effects of contact resistance between strands with Cron-Cr coating in cable-in-conduit conductors

机译:引入电缆的导体中带Cr /非Cr涂层的绞合线之间的接触电阻的影响

获取原文
获取原文并翻译 | 示例

摘要

We have fabricated an experimental equipment which mechanically applies a force to stacked strands with two kinds (0 and 60 degrees) of crossing angles. We measured the contact resistance between the strands, the contact force applied to the strands and the deformation of the strands at three temperatures (293 K, 77 K and 4.2 K). We investigated two kinds of strands (bare surface and with Cr plate). From the experimental results, in the case of a line contact (when the intersection angle's 0 degree) at liquid helium temperature, the ranges of the surface resistance of the Cr plated strands were between 4.3 × 10-8 and 1.7 × 10-7 Ωm2, while the resistance of the bare strands were between 9.2 × 10-9 and 2.7 × 10-8 Ωm2. Hence, effects of the Cr coating on the surface of the strands were clearly observed. The difference of the surface resistance appears to slightly depend on the intersection angles of the contact strands. The obtained results become fundamental data to simulate an electric circuit model of multi-stranded conductors and to estimate inter-strand coupling losses in the conductors.
机译:我们已经制造出一种实验设备,该设备以两种交叉角度(0和60度)机械地向堆叠的线束施加力。我们测量了绞线之间的接触电阻,施加在绞线上的接触力以及在三种温度(293 K,77 K和4.2 K)下绞线的变形。我们研究了两种绞线(裸露表面和带Cr板)。根据实验结果,在液氦温度下进行线接触(相交角为0度时)时,镀铬线束的表面电阻范围在4.3×10-8至1.7×10-7Ωm2之间。 ,而裸线的电阻在9.2×10-9和2.7×10-8Ωm2之间。因此,清楚地观察到了在股线表面上的Cr涂层的效果。表面电阻的差异似乎在一定程度上取决于接触线的交叉角。所获得的结果成为基础数据,以模拟多股导体的电路模型并估计导体中的股间耦合损耗。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号