We have measured the contact resistance between superconducting strands, which is a parameter of coupling losses in cable-in-conduit conductors. Varying the twist pitches of sub-cables in the multi-stranded cables, we prepared triplets made of three strands with four different intersection angles between the strands (0, 5, 7 and 13 degrees). The experimental results showed that the range of the surface resistances estimated by both the contact areas and the contact resistances depended on the intersection angles between the strands of the cable. When we estimate inter-strand coupling losses in the cable, we have to take the contact condition of the cable into consideration. The obtained results enlarge the database used to simulate an electric circuit model of multi-stranded conductors and to estimate inter-strand coupling losses in the conductors.
机译:我们已经测量了超导股线之间的接触电阻,这是导管内电缆导体中耦合损耗的参数。改变多股电缆中子电缆的扭绞节距,我们准备了由三股绞合而成的三元组,绞合之间的夹角为四个不同(0、5、7和13度)。实验结果表明,通过接触面积和接触电阻估算的表面电阻范围取决于电缆绞线之间的交角。当我们估计电缆中的绞线间耦合损耗时,我们必须考虑电缆的接触条件。获得的结果扩大了用于模拟多股导体的电路模型和估计导体中的股间耦合损耗的数据库。