摘要

AIMS—To determine the interobserver and the intraobserver reliability of a published classification scheme for corneal topography in normal subjects using the absolute scale.
METHOD—A prospective observational study was done in which 195 TMS-1 corneal topography maps in the absolute scale were independently classified twice by three classifiers—a cornea fellow, an ophthalmic technician, and an optometrist. From these observations the interobserver reliability for each category and the intraobserver reliability for each observer were determined in terms of the median weighted kappa statistic for each category and for each observer.
RESULTS—For interobserver reliability, the median weighted kappa statistic for each category varied from 0.72 to 0.97 and for intraobserver reliability the range was 0.79 to 0.98.
CONCLUSION—This classification scheme is extremely robust and even in the hands of less experienced observers with minimal training it can be relied upon to provide consistent results.

Keywords: cornea; topography; classification; reliability
机译:目的:使用绝对标度确定正常受试者角膜地形图分类方案的观察者间和观察者内可靠性。
方法:进行了一项前瞻性观察性研究,其中195个TMS-1角膜地形图在绝对值范围内量表由三个分类器(角膜研究员,眼科技术员和验光师)独立地进行了两次分类。从这些观察中,每个类别的观察者间可靠性和每个观察者的内部观察者可靠性是根据每个类别和每个观察者的中值加权Kappa统计量确定的。
结果-对于观察者之间的可靠性,以下各项的中值加权Kappa统计量每个类别的范围从0.72到0.97,对于观察者内部可靠性,范围是0.79到0.98。
结论—这种分类方案非常可靠,即使是经验不足的观察员也只需很少的培训就可以依靠它来提供一致的结果。

关键词:角膜;地形;分类;可靠性