首页> 美国卫生研究院文献>Revista Brasileira de Ortopedia >PROSPECTIVE STUDY ON TACTILE SENSITIVITY IN THE HANDS OF A BRAZILIAN POPULATION USING THE PRESSURE-SPECIFIED SENSORY DEVICE
【2h】

PROSPECTIVE STUDY ON TACTILE SENSITIVITY IN THE HANDS OF A BRAZILIAN POPULATION USING THE PRESSURE-SPECIFIED SENSORY DEVICE

机译:基于压力感测装置的巴西人口触觉敏感性的前瞻性研究

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Objective: To evaluate the pressure perception thresholds on the pulp of two fingers (index and little fingers), among a Brazilian population with no nerve injury or neuropathy. Methods: We used the Pressure-Specified Sensory Device (a computerized device) to derive static and dynamic normal pressure perception thresholds and two-point discrimination distances. Results: We tested finger sensitivity on 30 volunteers. Significance analyses were performed using the Student t test. The mean values (g/mm2) for static one and two-point pressure thresholds (s1PD, s2PD) and dynamic one and two-point discrimination (m1PD, m2PD) in the dominant index finger were: s1PD = 0.4, m1PD = 0.4, s2PD = 0.48, m2PD = 0.51. Conclusion: There was no significant difference in sensitivity between the dominant and nondominant hands.