首页> 外文会议>ASME InterPack Conference >STRESS ISOLATION STRUCTURES IN MEMS GYROSCOPE PACKAGES
【24h】

STRESS ISOLATION STRUCTURES IN MEMS GYROSCOPE PACKAGES

机译:MEMS陀螺盒中的应力隔离结构

获取原文

摘要

This paper describes the impact of lead frame design to minimize mechanical and thermal stresses to a MEMS (micro-electromechanical systems) gyroscope in a plastic premold cavity package. Design ideas for incorporating stress-isolation structures by etching the die paddle in a lead frame were evaluated with finite element modeling (FEM) and experimental verifications. The results showed that the null drift due to external mechanical stress was significantly improved by more than one order of magnitude, and the temperature variation of the device output was also improved by 30 %, both by mounting the device on the lead frame etched with stress-isolation structures.
机译:本文介绍了引线框架设计的影响,以使MEMS(微机电系统)陀螺仪在塑料最侧面腔封装中最小化机械和热应力。通过有限元建模(FEM)和实验验证评估通过蚀刻引线框架中的管芯焊盘来掺入应力隔离结构的设计思路。结果表明,由于外部机械应力引起的空漂移显着提高了多余的数量级,并且通过将设备安装在带应力的引线框架上的装置上,器件输出的温度变化也得到了30%的提高了30% - 溶解结构。