首页> 外文会议>Electronics Packaging Technology Conference >Calibration of Equivalent Finite Element Model for Packaged Printed Circuit Board by Experimental Modal Analysis
【24h】

Calibration of Equivalent Finite Element Model for Packaged Printed Circuit Board by Experimental Modal Analysis

机译:实验模态分析校准封装印刷电路板的等效有限元模型

获取原文

摘要

In this work, the experimental modal analysis (EMA) was performed to establish an equivalent finite element (FE) model for a standard JEDEC drop test printed circuit board (PCB) mounted with packages in a full array. Material properties of the equivalent FE model of the packaged PCB were calibrated through an optimization process with respect to natural frequencies based on EMA results obtained with a free boundary condition. The model was then applied to determine screwing tightness of the packaged PCB corresponding to a fixed boundary condition with the four corners of the PCB constrained, as defined by JEDEC for a board-level drop test.
机译:在这项工作中,执行实验模态分析(EMA)以建立一个等效的有限元(FE)模型,用于标准JEDEC跌落试验印刷电路板(PCB)安装有完整阵列的封装。通过基于具有自由边界条件获得的EMA结果,通过优化过程校准封装PCB等同Fe模型的材料特性。然后应用该模型以确定与固定边界条件相对应的封装PCB的拧紧密封性,其由PCB的四个角度受到限制,如JEDEC用于板级跌落测试。