首页> 外文会议>International conference on phenomena in ionized gases;ICPIG 2007 >Thermal plasma diagnostic method based on the ratio of plasmaradiation emitted in various spectral regions
【24h】

Thermal plasma diagnostic method based on the ratio of plasmaradiation emitted in various spectral regions

机译:基于在各个光谱区域发射的等离子体辐射比的热等离子体诊断方法

获取原文

摘要

A new diagnostic method to evaluate the thermal plasma temperature is investigated for argon and80%Ar-20%H2 plasmas at atmospheric pressure. Its principle is to use the different evolutionsaccording to the temperature of the emitted plasma radiation in various spectral regions. Thistechnique needs a preliminary study to calculate this evolution and we will present the bases ofthis calculation. An experimental study is developed to validate the method. The setup iscomposed of a wall-stabilised arc and a multichannel spectrometer. Some usual diagnosticmethods are applied to calculate the temperature on the axis of the cylindrical plasma. Theseresults are compared with the new technique. We limit to work on the spectral regions between300 nm and 1100 nm where self-absorption is often negligible. First experimental results arepresented and discussed for an argon plasma.
机译:研究了一种大气压下氩气和80%Ar-20%H2等离子体的评估热等离子体温度的新诊断方法。其原理是根据在各个光谱区域中发射的等离子体辐射的温度使用不同的演化。该技术需要进行初步研究以计算这种演变,我们将介绍该计算的基础。进行了实验研究以验证该方法。该装置由壁稳定电弧和多通道光谱仪组成。应用一些常用的诊断方法来计算圆柱形等离子体轴上的温度。将这些结果与新技术进行比较。我们限制在300 nm至1100 nm之间的光谱区域工作,在这些光谱区域,自吸收通常可以忽略不计。提出和讨论了氩等离子体的第一个实验结果。