首页> 外文OA文献 >EVALUASI KINERJA RUANG SMK NEGERI 5 BANDUNG DENGAN METODE PERFORMANCE METRIC : Studi Kasus Laboratorium Komputer
【2h】

EVALUASI KINERJA RUANG SMK NEGERI 5 BANDUNG DENGAN METODE PERFORMANCE METRIC : Studi Kasus Laboratorium Komputer

机译:用绩效考核法评价万隆职业学校的职业学校绩效:以计算机实验室为例

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Sekolah Menengah Kejuruan merupakan lembaga pendidikan tingkat menengah yang mempersiapkan lulusannya mampu bekerja dalam bidang tertentu. SMK Negeri 5 Bandung memiliki ruang laboratorium komputer untuk kompetensi keahlian menggambar dengan perangkat lunak. Kondisi ruangan laboratorium komputer dalam hal pencahayaan masih gelap, sedangkan dalam hal penghawaan di laboratorium komputer ini kurang nyaman karena terasa pengap. Penelitian ini bertujuan untuk menghasilkan gambaran umum mengenai kondisi laboratorium komputer, mengetahui lebih lanjut mengenai proporsi ruang, pencahayaan gabungan, dan sirkulasi udara di laboratorium komputer. Penelitian ini membahas mengenai evaluasi kinerja ruang SMK Negeri 5 Bandung dengan metode performance metric studi kasus laboratorium komputer. Penelitian ini merupakan jenis penelitian deskriptif evaluatif dengan menggunakan metode performance metric, mencakup tiga aspek yang ditinjau yaitu, proporsi ruang meliputi luas ruang, tata letak furniture, dan sirkulasi di ruang laboratorium komputer. Aspek yang kedua yaitu intensitas pencahayaan gabungan, dan aspek yang ketiga yaitu sirkulasi udara. Untuk pengukuran mengenai proporsi ruang dilakukan dengan cara mengukur ruangan menggunakan Meteran Roll, pengukuran intensitas pencahayaan gabungan menggunakan light meter, dan pengukuran sirkulasi udara menggunakan Anemometer. Metode pengumpulan data dengan cara observasi, dokumentasi, pengukuran dan wawancara. Instrumen penelitian menggunakan lembar observasi. Data perolehan pengukuran dari metrik-metrik yang telah disusun kemudian dibandingkan dengan standar PERMENDIKNAS No. 40 Tahun 2008 dan SNI yang berlaku. Hasil penelitian menunjukkan bahwa kinerja ruangan tersebut ditinjau dari proporsi ruang untuk luas ruang, memiliki panjang 15,85 m dan lebar 8,85 m adalah terlalu besar untuk jumlah murid 35 orang. Furniture pada ruang laboratorium komputer masih kurang lengkap dan sebagian kondisinya rusak, beberapa sudah memenuhi standar dan ada yang belum memenuhi standar. Ruang sirkulasi di dalam kelas sebesar 2,08 m, jika dibandingkan dengan standar sirkulasi terlalu besar, karena pada standar lebar sirkulasi untuk dua orang berjalan yaitu 1,6 m. Intensitas pencahayaan gabungan yaitu 341,54 lux, hal tersebut cukup memenuhi standar yang disarankan SNI, namun disalah satu sisi masih gelap. Untuk ventilasi yang terdapat pada ruangan ini adalah 8,4 % dari luas lantai dan sudah memenuhi standar hanya kondisi beberapa jendela rusak, sehingga udara yang masuk hanya 0,03 m/detik, menyebabkan temperatur ruangan panas. Solusi yang disarankan untuk proporsi ruang yaitu penataan kembali furniture, mengganti serta menambahkan beberapa furniture. Sedangkan untuk pencahayaan sebaiknya meminimalisir pencahayaan buatan. Sedangkan pada area yang sangat terang sebaiknya menggunakan vertical blind yang berguna untuk mengurangi cahaya yang masuk agar sesuai standar. ududVocational School is a secondary education institution that prepares graduates able to work in a particular field. SMK Negeri 5 Bandung has a computer lab space for drawing skills competency with software. The Conditions of computer lab room is still dark in terms of lighting, while in terms of air circulation in the computer lab is less convenient because it feels stuffy. This study aims to produce an overview of the computer laboratory condition, learn more about the proportion of space, combined lighting and air circulation in the computer lab 5 Vocational High School Bandung. This study discusses the performance evaluation of space in 5 Vocational High School Bandung with the case study of computer lab with performance metrics method. This research is a descriptive evaluative research using performance metrics method which includes three aspects to be reviewed namely, the proportion of space includes spacious living room, furniture layout, and circulation in the computer lab. The second aspect is the combined illumination intensity, and the third aspect is the air circulation. For the measurement of the proportion of space was conducted by measuring the room using the Meter Roll, the combined illumination intensity measurements using a light meter, and air circulation measurements using anemometer. For the data collection; observation, documentation, measurement, and interview were employed. While, for The research instrument using the observation sheet. The data acquisition of measurement metrics which had been compiled, was compared with standar permendiknas No.40 Year 2008 and Indonesia National Standard (SNI) regulations. udThe results showed that the performance of the space in terms of the proportion of space for living space as a length of 15.85 m and a width of 8.85 m is too large for 35 students. Then the furnitures in the computer lab space are still not complete and partially in damaged condition, do not meet the standards, but some already fulfill the existing standards. For the circulation space in the computer laboratory by 2.08 m width, when it was compared with the standard circulation is too large, because the standard width of circulation for two people walking is at 1.6 m. The combined illumination intensity is 341.54 lux, it is sufficient for recommended standard of SNI, but at one side is still dark. For ventilation in the computer lab is 8.4% of the floor area and it meets the standard conditions even though, some windows are broken , so that the incoming air is only 0.03 m / sec, which causes the heat of the temperature in the room. For the solution, it is suggested to organize the furniture due to the space proportion, replace and add some furniture. As for the lighting it should lessen the use of artificial lighting. According to the principle of performance metric, it is better to decrease the energy consumption. While in a very bright area it should use vertical blinds which are useful to reduce the incoming light to fit standard.
机译:职业高中是中等教育机构,它为毕业生做好在某些领域工作的准备。 SMK Negeri 5万隆拥有一间计算机实验室,可熟练使用软件进行绘画技能。就照明而言,计算机实验室室的条件仍然很暗,而在通风的情况下,计算机实验室由于感到闷气而并不舒适。这项研究旨在对计算机实验室的状况进行一般性描述,以了解有关计算机实验室中空间比例,组合照明和空气流通的更多信息。这项研究讨论了使用计算机实验室案例研究的性能度量方法对SMK Negeri 5 Bandung的空间性能进行评估。这项研究是一种使用性能指标方法的评估性描述性研究,涵盖了三个方面的内容,即空间比例包括空间面积,家具布局和计算机实验室室内的流通。第二方面是综合照明强度,第三方面是空气流通。对于空间比例的测量,该测量是通过使用滚动仪测量房间,使用测光仪测量组合照明强度以及使用风速仪测量空气流通量来进行的。通过观察,记录,测量和访谈的数据收集方法。研究仪器使用观察表。然后将从已编译的度量中获得的测量数据与PERMENDIKNAS标准No. 2008年第40号和适用的SNI。结果表明,就35个学生的人数而言,长度为15.85 m,宽度为8.85 m的房间在房间区域中所占空间的比例太大。计算机实验室室中的家具仍然不完整,有些情况已损坏,有些符合标准,有些不符合标准。与标准循环相比,该循环空间为2.08 m,因为两个人行走的标准循环宽度为1.6 m。组合照明强度为341.54 lux,足以满足SNI建议的标准,但一侧仍然很暗。该房间的通风面积为地板面积的8.4%,仅满足部分破窗条件,因此进入的空气仅为0.03 m / sec,从而导致房间温度升高。建议的解决方案是重新布置家具,更换和添加​​一些家具。至于照明,最好尽量减少人工照明。而在非常明亮的区域中,应使用垂直百叶窗,该百叶窗有助于减少入射光以达到标准。国际职业学校是一所中等教育机构,为能够在特定领域工作的毕业生做好准备。万隆国立职业学校5有一个计算机实验室,可以利用软件来绘画技能。就照明而言,计算机实验室机房的条件仍然很暗,而在计算机实验室中的空气流通方面,由于感觉闷闷不便。这项研究旨在概述计算机实验室的状况,了解更多有关万隆5职业高中计算机实验室中空间所占比例,组合照明和空气流通的信息。本研究以性能度量方法为例,对万隆五中职业技术学校空间绩效进行了探讨。这项研究是使用性能指标方法的描述性评估研究,其中包括三个方面需要审查,即空间比例包括宽敞的客厅,家具布局和计算机实验室中的流通。第二方面是组合照明强度,第三方面是空气循环。对于空间比例的测量,通过使用米辊测量房间,使用光度计测量组合的照明强度以及使用风速计测量空气循环来进行。用于数据收集;进行观察,记录,测量和访谈。同时,对于研究仪器使用观察表。将已汇编的度量标准的数据获取与教育部的2008年第40号国家标准和印度尼西亚国家标准(SNI)法规进行了比较。 ud结果表明,该空间的性能相对于居住空间的空间比例而言,长度为15.85 m,宽度为8.85 m,对于35名学生来说太大了。然后,计算机实验室空间中的家具仍不完整且部分处于损坏状态,不符合标准,但有些已经满足了现有标准。对于计算机实验室中流通宽度为2.08 m的空间,与标准流通相比,它太大了,因为两个人行走的标准流通宽度为1.6 m。组合照明强度为341.54 lux,足以满足推荐的SNI标准,但一侧仍然很暗。在计算机实验室中,通风量占建筑面积的8.4%,即使某些窗户被打破,它也符合标准条件,因此进入的空气仅为0.03 m / sec,这会导致室内温度升高。对于该解决方案,建议根据空间比例组织家具,更换并添加一些家具。至于照明,应减少使用人工照明。根据性能指标的原则,最好减少能耗。在非常明亮的区域中,应使用垂直百叶窗,以减少入射光以使其符合标准。

著录项

  • 作者

    Novyanti Yuwita;

  • 作者单位
  • 年度 2014
  • 总页数
  • 原文格式 PDF
  • 正文语种 en
  • 中图分类

相似文献

  • 外文文献
  • 中文文献
  • 专利

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号