首页> 外文OA文献 >Investigation of a real-time location system of corneal astigmatic axis
【2h】

Investigation of a real-time location system of corneal astigmatic axis

机译:角膜散轴实时定位系统的研究

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Abstract Background To construct a real-time computerized location system (RCLS) to analyze and display the axis of corneal astigmatism and to compare its accuracy with the Scheimpflug method. Methods Fifty-seven eyes of 39 volunteers with corneal astigmatism more than 1.00 diopter (D) were recruited. The RCLS was composed of a circular light-emitting diode (LED) light source, surgical microscope, surgical video system, computer and self-programming image analysis software. Scheimpflug imaging measurements (Pentacam HR, Oculus, Wetzlar, Germany) were performed on all subjects to determine the axis and power of corneal astigmatism. Thereafter, the axis of corneal astigmatism was analyzed in real-time and displayed by the RCLS on supine position, and videos were recorded. The MB-Ruler 4.0 software was used to measure the astigmatic axis. The accuracy of the RCLS was compared with the Scheimpflug method. Results The RCLS was able to display the axis of corneal astigmatism in real-time. The axial deviation of corneal astigmatism between the two methods was 0.63 ± 3.78° when astigmatism was 1.00 to 2.00 D and decreased to 0.06 ± 1.38° when astigmatism was greater than 2.00 D. A linear correlation of astigmatic axis was noted between the two methods: AxisRCLS = 1.01 × AxisScheimpflug − 1.02 (R2 = 0.998, P < 0.001). The Bland-Altman analysis revealed that the RCLS agreed sufficiently well with the Scheimpflug method. Conclusions The RCLS can accurately analyze and display the axis for corneal astigmatism greater than 1.00 D in real-time. The RCLS simplifies marking procedures and may have potential clinical application to improve the postoperative visual outcomes in surgical correction of corneal astigmatism.
机译:抽象背景构建实时计算机化位置系统(RCLS)来分析和显示角膜散光轴,并比较其与Scheimpflug方法的准确性。方法招募了57名志愿者的五十七名眼球散差超过1.00分屈光度(D)的眼睛。 RCLS由圆形发光二极管(LED)光源,手术显微镜,外科手术系统,计算机和自我编程图像分析软件组成。 Scheimpflug成像测量(Pentacam Hr,Oculus,Wetzlar,德国)是对所有受试者进行的,以确定角膜散光的轴和力量。此后,实时分析角膜像散的轴,并由仰卧位上的RCL显示,并记录视频。 MB-Ruler 4.0软件用于测量散光轴。将RCLS的准确性与Scheimpflug方法进行比较。结果RCLS能够实时地显示角膜散光轴。当像散散散,两张散差为0.63±3.78°时,两种方法之间的轴向偏差为0.63±3.78°当散光大于2.00°D时达到0.06±1.38°。在两种方法之间注意到散光轴的线性相关性: Axisrcls = 1.01×Axisscheimpflug - 1.02(R2 = 0.998,P <0.001)。 Bland-Altman分析显示,RCLS与Scheimpflug方法充分吻合。结论RCLS可以在实时分析和显示角膜散域的轴线,以实时大于1.00 D。 RCLS简化了标记程序,并且可能具有潜在的临床应用,以改善角膜散光的外科矫正中的术后视觉结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号