首页> 美国政府科技报告 >Experimental Study of the Pressure Losses in Converging Flow Fittings Used in Exhaust Systems
【24h】

Experimental Study of the Pressure Losses in Converging Flow Fittings Used in Exhaust Systems

机译:排气系统中用于流动配件压力损失的实验研究

获取原文

摘要

A study was conducted to correlate pressure losses for all fittings normally used in industrial ventilation exhaust systems. The project was divided into two parts. In the first part an experimental investigation was made of pressure losses in 16 converging flow fittings with 8 inch common seam diameters which covered a wide range of branch tap and main fitting body styles. The second part of the study correlated pressure losses on a generalized basis which would be valid for all converging flow fittings normally used in industry. Fittings with take/off diameters from 3 to 16 inches were studied. Flow conditions most commonly used in industrial ventilation systems were used; branch to main upstream velocity ratios varied from 0.75 to 6. Branch entry angles of 30, 45, and 90 degrees were studied. Branch and main loss coefficients were found to correlate with good agreement when plotted against the ratio of branch to upstream volume flow rate. Branch and main loss coefficients were found to be significantly affected by the three types of branch tap entrance (sharp, rolled, and round edge).