首页> 美国政府科技报告 >Walk-Through Survey Report of Electric Storage Battery, Inc., Dallas, Texas
【24h】

Walk-Through Survey Report of Electric Storage Battery, Inc., Dallas, Texas

机译:德克萨斯州达拉斯Electric storage Battery公司的演练调查报告

获取原文

摘要

Worker exposure to sulfuric-acid (7664939) (H2SO4), stibine (7803523) (SbH3), arsine (7784421) (AsH3) and lead (7439921) (Pb) was surveyed at Electric Storage Battery, Incorporated, (SIC-3692) in Dallas, Texas, on December 5, 1978. The company was under consideration for inclusion in an in depth industrial hygiene or epidemiological research study involving occupational exposure to H2SO4 mist. The company manufactured lead acid batteries and employed 170 workers. Personal records, death certificates and disability and pension information were available. The company provided medical, industrial hygiene and safety programs. General area samples were taken and concentrations of H2SO4 mist, SbH3, AsH3 and Pb were measured. Concentrations of H2SO4 ranged from 0.064 to 0.141 milligrams per cubic meter (mg/cu m). SbH3, AsH3 and Pb concentrations were 0.031, 0.011 and 0.498 mg/cu m, respectively. The author concludes that the toxicological nature of contaminants present in the general area samples would distort and complicate the findings of health effects due to H2SO4 exposure. They do not recommend this facility for inclusion in the proposed study.

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号