首页> 美国政府科技报告 >Preliminary Design of the Cryogenic Cooled Limb Scanning Interferometer Radiometer (CLIR)
【24h】

Preliminary Design of the Cryogenic Cooled Limb Scanning Interferometer Radiometer (CLIR)

机译:低温冷却肢体扫描干涉仪辐射计(CLIR)的初步设计

获取原文

摘要

The preliminary design of the cryogenic cooling system for the Cryogenic Cooled Limb Scanning Interferometer Radiometer (CLIR) instrument to be flown on the Atmospheric Magnetospheric Physics Satellite (AMPS) was studied. The top level trade studies were extensive due to the instrument requirement for cooling at three temperature levels as opposed to the two levels initially described for the instrument. Approximately 12 different combinations of cryogens were investigated. The basic lifetime requirement for the instrument was 30 days. However, studies were also conducted for a follow-up mission requiring a 1 year lifetime. The top level trades led to the selection of a single stage supercritical helium baseline.