首页> 美国政府科技报告 >Study of the Effect of Apparent Strain on Thermal Stress Measurement for Two Types of Elevated Temperature Gages
【24h】

Study of the Effect of Apparent Strain on Thermal Stress Measurement for Two Types of Elevated Temperature Gages

机译:表观应变对两种高温测温仪热应力测量影响的研究

获取原文

摘要

A weldable type strain gage was used to measure low level thermal stress in an elevated temperature environment. Foil strain gages used in a comparative manner reveal that the apparent strain of weldable strain gages is not sufficiently known to acquire accurate low level thermal stress data. Apparent strain data acquired from coupon tests reveals a large scatter in apparent strain characteristics among the weldable strain gages. It is concluded that apparent strain data for individual weldable strain gages must be required prior to installation if valid thermal stress data is to be obtained through the temperature range of room temperature to 755 K (900 F).