首页> 外文期刊>Radiation Physics and Chemistry >Contact radiotherapy using a 50 kV X-ray system: Evaluation of relative dose distribution with the Monte Carlo code PENELOPE and comparison with measurements
【24h】

Contact radiotherapy using a 50 kV X-ray system: Evaluation of relative dose distribution with the Monte Carlo code PENELOPE and comparison with measurements

机译:使用50 kV X射线系统的接触式放射疗法:使用蒙特卡罗代码PENELOPE评估相对剂量分布并与测量结果进行比较

获取原文
获取原文并翻译 | 示例

摘要

This paper presents a dosimetric study concerning the system named "Papillon 50" used in the department of radiotherapy of the Centre Antoine-Lacassagne, Nice, France. The machine provides a 50 kVp X-ray beam, currently used to treat rectal cancers. The system can be mounted with various applicators of different diameters or shapes. These applicators can be fixed over the main rod tube of the unit in order to deliver the prescribed absorbed dose into the tumor with an optimal distribution. We have analyzed depth dose curves and dose profiles for the naked tube and for a set of three applicators. Dose measurements were made with an ionization chamber (PTW type 23342) and Gafchromic films (EBT2). We have also compared the measurements with simulations performed using the Monte Carlo code PENELOPE. Simulations were performed with a detailed geometrical description of the experimental setup and with enough statistics. Results of simulations are made in accordance with experimental measurements and provide an accurate evaluation of the dose delivered. The depths of the 50% isodose in water for the various applicators are 4.0, 6.0, 6.6 and 7.1 mm. The Monte Carlo PENELOPE simulations are in accordance with the measurements for a 50 kV X-ray system. Simulations are able to confirm the measurements provided by Gafchromic films or ionization chambers. Results also demonstrate that Monte Carlo simulations could be helpful to validate the future applicators designed for other localizations such as breast or skin cancers. Furthermore, Monte Carlo simulations could be a reliable alternative for a rapid evaluation of the dose delivered by such a system that uses multiple designs of applicators.
机译:本文提出了有关名为“ Papillon 50”的系统的剂量学研究,该系统在法国尼斯的Antoine-Lacassagne中心放疗科使用。该机器提供了一个50 kVp X射线束,目前用于治疗直肠癌。该系统可以安装有不同直径或形状的各种涂药器。这些施加器可以固定在单元的主杆管上,以便以最佳分布将规定的吸收剂量输送到肿瘤中。我们分析了裸管和一组三个涂抹器的深度剂量曲线和剂量分布。用电离室(PTW 23342型)和全色膜(EBT2)进行剂量测量。我们还将测量结果与使用蒙特卡罗代码PENELOPE进行的仿真进行了比较。通过对实验装置进行详细的几何描述并具有足够的统计信息来执行模拟。模拟结果是根据实验测量得出的,并提供了对所输送剂量的准确评估。对于各种施药器,水中50%的等剂量物质的深度分别为4.0、6.0、6.6和7.1毫米。蒙特卡洛PENELOPE模拟符合50 kV X射线系统的测量结果。仿真能够确认Gafchromic膜或电离室提供的测量结果。结果还表明,蒙特卡洛模拟可能有助于验证未来针对其他部位(例如乳腺癌或皮肤癌)设计的涂药器。此外,蒙特卡洛模拟可能是一种可靠的替代方法,可以快速评估由使用多种设计的施药器的系统提供的剂量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号