首页> 外文期刊>Analytical and bioanalytical chemistry >Enhanced metabolite profiling using a redesigned atmospheric pressure chemical ionization source for gas chromatography coupled to high-resolution time-of-flight mass spectrometry
【24h】

Enhanced metabolite profiling using a redesigned atmospheric pressure chemical ionization source for gas chromatography coupled to high-resolution time-of-flight mass spectrometry

机译:使用重新设计的常压化学电离源进行改进的代谢物分析,用于气相色谱和高分辨率的飞行时间质谱

获取原文
获取原文并翻译 | 示例

摘要

An improved atmospheric pressure chemical ionization (APCI II) source for gas chromatography-high-resolution time-of-flight mass spectrometry (GC-HRTOFMS) was compared to its first-generation predecessor for the analysis of fatty acid methyl esters, methoxime-trimethylsilyl derivatives of metabolite standards, and cell culture supernatants. Reductions in gas turbulences and chemical background as well as optimized heating of the APCI II source resulted in narrower peaks and higher repeatability in particular for late-eluting compounds. Further, APCI II yielded a more than fourfold median decrease in lower limits of quantification to 0.002-3.91 mu M along with an average 20 % increase in linear range to almost three orders of magnitude with R (2) values above 0.99 for all metabolite standards investigated. This renders the overall performance of GC-APCI-HRTOFMS comparable to that of comprehensive two-dimensional gas chromatography (GC x GC)-electron ionization (EI)-TOFMS. Finally, the number of peaks with signal-to-noise ratios greater than 20 that could be extracted from metabolite fingerprints of pancreatic cancer cell supernatants upon switching from the APCI I to the APCI II source was more than doubled. Concomitantly, the number of identified metabolites increased from 36 to 48. In conclusion, the improved APCI II source makes GC-APCI-HRTOFMS a great alternative to EI-based GC-MS techniques in metabolomics and other fields.
机译:将用于气相色谱-高分辨率飞行时间质谱(GC-HRTOFMS)的改进型常压化学电离(APCI II)源与其第一代前辈用于脂肪酸甲酯,甲氧肟三甲基甲硅烷基分析的比较代谢物标准品的衍生物和细胞培养上清液。减少气体湍流和化学背景,以及优化APCI II离子源的加热,可得到更窄的峰和更高的重复性,尤其是对于晚洗脱化合物而言。此外,APCI II的定量下限中值下降了四倍以上,为0.002-3.91μM,线性范围平均增加了20%,几乎达到三个数量级,所有代谢物标准品的R(2)值均超过0.99。调查。这使得GC-APCI-HRTOFMS的整体性能可与全面二维气相色谱(GC x GC)-电子电离(EI)-TOFMS媲美。最后,当从APCI I切换到APCI II来源时,可以从胰腺癌细胞上清液的代谢物指纹中提取的信噪比大于20的峰数增加了一倍以上。随之而来的是,鉴定出的代谢物数量从36种增加到48种。总而言之,改进的APCI II来源使GC-APCI-HRTOFMS成为代谢组学和其他领域中基于EI的GC-MS技术的绝佳替代品。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号