首页> 外文期刊>Journal of clinical monitoring and computing >Use of the MIRUS? system for general anaesthesia during surgery: a comparison of isoflurane, sevoflurane and desflurane
【24h】

Use of the MIRUS? system for general anaesthesia during surgery: a comparison of isoflurane, sevoflurane and desflurane

机译:使用mirus? 手术期间全身麻醉系统:异氟醚,七氟醚和DESFLURANE的比较

获取原文
获取原文并翻译 | 示例

摘要

The MIRUS? system enables automated end-expired control of volatile anaesthetics. The device is positioned between the Y-piece of the breathing system and the patient’s airway. The system has been tested in vitro and to provide sedation in the ICU with end-expired concentrations up to 0.5 MAC. We describe its performance in a clinical setting with concentrations up to 1.0 MAC. In 63 ASA II–III patients undergoing elective hip or knee replacement surgery, the MIRUS? was set to keep the end-expired desflurane, sevoflurane, or isoflurane concentration at 1 MAC while ventilating the patient with the PB-840 ICU ventilator. After 1?h, the ventilation mode was switched from controlled to support mode. Time to 0.5 and 1 MAC, agent usage, and emergence times, work of breathing, and feasibility were assessed. In 60 out of 63 patients 1.0 MAC could be reached and remained constant during surgery. Gas consumption was as follows: desflurane (41.7?±?7.9?ml?h_(?1)), sevoflurane (24.3?±?4.8?ml?h_(?1)) and isoflurane (11.2?±?3.3?ml h_(?1)). Extubation was faster after desflurane use (min:sec): desflurane 5:27?±?1:59; sevoflurane 6:19?±?2:56; and isoflurane 9:31?±?6:04. The support mode was well tolerated. The MIRUS? system reliable delivers 1.0 MAC of the modern inhaled agents, both during mechanical ventilation and spontaneous (assisted) breathing. Agent usage is highest with desflurane (highest MAC) but results in the fastest emergence. Trial registry number : Clinical Trials Registry, ref.: NCT0234509.
机译:米兰?系统使自动化的挥发性麻醉剂无限期控制。该装置位于呼吸系统的Y型件和患者的气道之间。该系统已经在体外进行了测试,并在ICU中提供镇静的浓度高达0.5 Mac。我们在临床环境中描述其性能,浓度高达1.0 mac。在63名ASA II-III患者接受选修髋关节或膝关节置换手术,米兰?在用PB-840 ICU呼吸机通风时,将七氟醚或异氟醚浓度保持在1mAc下保持在1mAc中。在1?H之后,从控制到支持模式切换通气模式。时间达到0.5和1 Mac,代理使用和出现时间,呼吸工作和可行性进行了评估。在63例患者中有60例,在手术期间可以达到1.0mC1.0 MAC。气体消耗如下:desflanane(41.7?±7.9?ml = 7.9?h _(α1)),七氟醚(24.3?±4.8?ml = _(α1))和异氟醚(11.2?±3.3?ml h_ (?1))。脱氟丙烷使用后拔管(min:sec):desfluane 5:27≤α1:59;七氟醚6:19?±2:56;和异氟烷9:31?±6:04。支持模式耐受良好。米兰?在机械通风和自发(辅助)呼吸期间,系统可靠地提供现代吸入剂的1.0 Mac。代理使用与Desfluane(最高MAC)最高,但导致最快的出现。试验登记号:临床试验登记处,REF。:NCT0234509。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号