首页> 外文期刊>Journal of Analytical Toxicology >Development of a Liquid Chromatography–Tandem Mass Spectrometry Method for the Simultaneous Determination of Four Cannabinoids in Umbilical Cord Tissue
【24h】

Development of a Liquid Chromatography–Tandem Mass Spectrometry Method for the Simultaneous Determination of Four Cannabinoids in Umbilical Cord Tissue

机译:液相色谱 - 串联质谱法同时测定脐带组织中四种大麻素

获取原文
获取原文并翻译 | 示例
           

摘要

In utero exposure to marijuana may cause various short- and long-term health problems, such as stillbirth, low birth weight and decreased cognitive function. Detection of in utero marijuana exposure with a relatively new specimen type, umbilical cord tissue, can be used to plan treatment and guide social management. In this study, a liquid chromatography–tandem mass spectrometry (LC–MS-MS) assay was developed for the simultaneous identification of four cannabinoids in umbilical cord tissue, including ?9-tetrahydrocannabinol (THC), 11-nor-9-carboxy-?9--THC (THC-COOH), 11-hydroxy-?9-THC (11-OH-THC) and cannabinol (CBN). Within- and between-run imprecision, accuracy, linearity, sensitivity, carryover, recovery, matrix effects and specificity were evaluated using drug-free umbilical cord tissue spiked with non-deuterated and deuterated standards. Calibration curves were reproducible and linear (r > 0.995) for all four analytes in the range of 0.2 ng/g lower limit of quantitation (LLOQ) and 30 ng/g upper limit of quantitation (ULOQ). Total imprecisions (% coefficient of variation) were 7.8% (THC), 13.3% (THC-COOH), 11.8% (11-OH-THC) and 10.6% (CBN) at low QC (n = 15, 0.25 ng/g), and were 7.2% (THC), 10.0% (THC-COOH), 9.5% (11-OH-THC) and 5.8% (CBN) at high QC (n = 15, 4 ng/g), respectively. No interfering substances were identified, and no carryover was observed. The average accuracies (N = 25) were 94–95%. The average recoveries observed for THC, THC-COOH, 11-OH-THC and CBN were 74, 82, 58 and 86%, respectively. By analyzing authentic clinical specimens that had been previously tested for cannabinoids by enzyme-linked immunoassay, positive and negative result agreements were 100 and 53.8%. In summary, the presented method can be used for the assessment of in utero exposure to four common cannabinoids.
机译:在UTERO暴露于大麻中可能导致各种短期和长期的健康问题,例如死产,低出生体重和认知功能减少。用相对较新的样品型脐带组织进行UTERO大麻接触的检测可用于规划治疗和指导社会管理。在该研究中,开发了一种液相色谱 - 串联质谱(LC-MS-MS)测定,用于同时鉴定脐带组织中的四种大麻素,包括α,包括α,11-氧化萘酚(THC),11- NOR-9-羧基 - ?9 - THC(THC-COOH),11-羟基 - α9-THC(11-OH-THC)和大麻酚(CBN)。使用无毒的脐带组织进行评估使用无氘和氘代标准的无毒的脐带组织来评估运行不精确,准确性,线性,灵敏度,携带,恢复,基质效应和特异性。校准曲线对于定量(LLOQ)的下限范围内的所有四个分析物(LLOQ)和定量下限(ULOQ)的范围,校准曲线是可再现和线性(R> 0.995)。在低QC(n = 15,0.25ng / g的低QC(n = 15,0.25ng / g)下为7.8%(THC),13.3%(THC-COOH),11.8%(11-OH-THC),11.8%(11-OH-THC)和10.6%(CBN) ),分别为7.2%(THC),10.0%(THC-COOH),9.5%(11-OH-THC),9.5%(11-OH-THC)和5.8%(CBN),分别为高QC(n = 15,4ng / g)。没有发现干扰物质,并且没有观察到残留物。平均准确性(n = 25)为94-95%。对于THC,THC-COOH,11-OH-THC和CBN观察到的平均回收率分别为74,82,58和86%。通过分析先前通过酶联免疫测定,阳性和阴性结果达到100和53.8%的大麻素测试的真正临床标本。总之,所提出的方法可用于对四种常见大麻素的子宫暴露进行评估。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号