Extent of tube-current reduction using sinogram affirmed iterative reconstruction in pediatric computed tomography: phantom study

机译:使用Sinogram的管电流减少程度肯定在儿科计算机断层扫描中的迭代重建:幻影研究

获取原文
获取原文并翻译 | 示例

摘要

BackgroundIterative image reconstruction techniques can produce diagnostic-quality computed tomography (CT) images with lower radiation dose.ObjectiveTo quantify the reduction in x-ray tube-current setting and optimize pediatric CT scans using different strengths of an iterative reconstruction technique.Materials and methodsThe head, chest and abdomen regions of an anthropomorphic phantom representing a 5-year-old patient were scanned using standard CT protocols. Images were reconstructed using filtered back projection and different strengths of a sinogram affirmed iterative reconstruction technique. Repeated measurements of contrast-to-noise ratios in the lungs, bone and soft-tissue regions of the phantom were carried out. Maximum increase in contrast-to-noise ratio with iterative reconstruction strength was identified and a tube-current reduction factor was calculated. Head scans were repeated with reduced tube current and compared to filtered back projection images.ResultsIterative reconstruction strength of 3 for head and chest images and 4 for abdomen images were optimum, resulting in contrast-to-noise ratio increase of about 50%. A tube-current reduction factor of 1.2 for head images was calculated. Images of the head acquired using reduced tube-current showed similar contrast-to-noise ratio as images form filtered back projection with full tube current.ConclusionOptimum strength of iterative reconstruction technique has been identified for head, chest and abdomen images. Reductions in tube current of 20%, resulting in similar radiation dose reduction, have been established.
机译:背景图像重建技术可以产生具有较低辐射剂量的诊断质量计算断层扫描(CT)图像。objectiveto量化X射线管电流设置的减少,并使用不同强度的迭代重建技术的不同优化小儿CT扫描。材料和方法,使用标准CT协议扫描代表5岁患者的人类幽灵的胸部和腹部区域。使用滤波后投影和Sinogram的不同强度重建图像肯定的迭代重建技术。进行肺部,骨骼和软组织区域中对比度噪音比的重复测量。鉴定了与迭代重建强度的对比度噪声比的最大增加,并计算了管电流减少因子。通过减小的管电流重复头部扫描,并与过滤的后投影图像相比。用于头部和胸部图像的3个术语重建强度和用于腹部图像的4个是最佳的,导致对比度达到噪声比率约为50%。计算头像的管电流缩小因子为1.2。使用降低管电流获取的头部的图像显示出类似的对比度与噪声比,因为图像形成具有全管电流的后射回投影。已经识别用于头部,胸部和腹部图像的迭代重建技术的能量。已经建立了20%的管电流降低,导致相似的辐射剂量减少。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号