首页> 外文期刊>Metalurgia >TESTS PERFORMED ON NICKEL LAYERS ELECTRO-PLATED ON MOULD PLATES OF STEEL CONTINUOUS CASTING
【24h】

TESTS PERFORMED ON NICKEL LAYERS ELECTRO-PLATED ON MOULD PLATES OF STEEL CONTINUOUS CASTING

机译:在钢连续铸造模具板上电镀的镍层进行测试

获取原文
获取原文并翻译 | 示例

摘要

This paper contains series of trials I conventional temperature conditions regarding the behaviour of the nickel coating on a copper support, in order to use them on the hardening of the mould plates surfaces from the continuous casting of steel. It presents the tests for a hetrtzian contact between a ball-shaped head and the samples made of copper and copper electrochemically coated with nickel in two different layers. This paper presents the first stage of a more comprehensive study, also including the tribological behaviour of various coatings on other support materials. The paper describes the test stand together with the methods which have been used and the experimental results obtained. These tests aimed to point out the moment of transition from the elastic range to the elasto-plastic range at the contact between the ball-shaped head and the sample. The experimental tests shown that, on the two nickel-coated samples, the coated layer presents almost the same tribological characteristics up to a value of Hertzian pressure sigma_k of about 2.200 Mpa. Above this value, on the sample with a nickel coated layer of 150 mu m in thickness, the plastic deformation process is intensifying.
机译:本文含有一系列试验I常规温度条件,关于铜支撑件上的镍涂层的行为,以便在模具板表面的连续铸造上使用它们。它呈现了球形头部与由铜和铜的样品在两层中用镍电化学涂覆的铜和铜之间的样品的测试。本文提出了一个更全面的研究的第一阶段,还包括各种涂料对其他支持材料的摩擦学行为。本文描述了测试台以及已使用的方法和获得的实验结果。这些测试旨在指出从弹性范围到球形头部和样品之间的接触的弹性范围的过渡的时刻。实验试验表明,在两个镍涂覆的样品上,涂层呈现几乎与约2.200MPa约2.200MPa的偏振压力Sigma_K的相同的摩擦学特征。在该值以上,在厚度为150μm的镍涂层的样品上,塑性变形过程强化。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号