首页> 外文期刊>Current medical imaging reviews. >Diagnostic Value of 320-Slice Coronary CT Angiography in Coronary Artery Disease: A Systematic Review and Meta-Analysis
【24h】

Diagnostic Value of 320-Slice Coronary CT Angiography in Coronary Artery Disease: A Systematic Review and Meta-Analysis

机译:320层冠状动脉CT血管造影在冠状动脉疾病中的诊断价值:系统评价和荟萃分析

获取原文
获取原文并翻译 | 示例

摘要

The aim of this study is to perform a systematic review and meta-analysis of the diagnostic value of 320-slice coronary computed tomography (CT) angiography in the diagnosis of coronary artery disease when compared to invasive coronary angiography. A search of different databases was conducted to identify studies investigating the diagnostic value of 320-slice coronary CT angiography. Sensitivity, specificity, positive and negative predictive value estimates pooled across studies were tested using a fixed effects model and analysed at patient-, vessel-and segment-based assessment. Twelve studies comprising 1592 patients (median, 63 patients, range, 37-240 patients) with a total of 2974 vessels and 21623 segments met selection criteria for inclusion in the analysis. Patients with a high prevalence of coronary artery disease were included in more than 70% of these studies. The mean values and 95% confidence interval (CI) of sensitivity, specificity, positive predictive value and negative predictive value of 320-slice coronary CT angiography were 96.3% (95% CI: 92.9%, 99.8%), 86.4% (95% CI: 77.8%, 94.9%), 89.6% (95% CI: 85.6%, 93.6%) and 93.2% (95% CI: 84.1%, 100%), at patient-based analysis; 91.8% (95% CI: 85.8%, 97.8%), 95.4% (95% CI: 93.6%, 97.1%), 85.9% (95% CI: 79.7%, 92%) and 97.4% (95% CI: 95.9%, 99.1%), at vessel-based analysis; 86.2% (95% CI: 81.8%, 90.6%), 96.5% (95% CI: 95.2%, 98%), 79.9% (95% CI: 75.3%, 84.6%) and 97.8% (95% CI: 96.7%, 99%), at segment-based analysis, respectively. The mean effective dose of 320-slice coronary CT angiography was 10.5 mSv (95% CI: 6.1, 14.8 mSv). Diagnostic value of 320-slice coronary CT angiography was not affected by different heart rates and calcium scores (p>0.05). This analysis shows that 320-slice coronary CT angiography has high diagnostic value in patients with high coronary artery disease prevalence. Relatively high radiation dose is mainly due to inclusion of patients with high heart rates and without using the advanced dose-reduction techniques, thus, further dose-saving strategies should be implemented to minimise the resultant radiation dose.
机译:这项研究的目的是对320层冠状动脉计算机断层扫描(CT)血管造影与有创冠状动脉造影相比的诊断价值进行系统的回顾和荟萃分析。进行了不同数据库的搜索,以鉴定研究320层冠状动脉CT血管造影的诊断价值的研究。使用固定效应模型测试跨研究汇总的敏感性,特异性,阳性和阴性预测值估计值,并在基于患者,血管和区段的评估中进行分析。十二项研究包括1592名患者(中位,63名患者,范围为37-240名患者),共有2974支血管和21623个节段,符合纳入分析的选择标准。这些研究中超过70%包括了冠心病患病率高的患者。 320层冠状动脉CT血管造影的敏感性,特异性,阳性预测值和阴性预测值的平均值和95%置信区间(CI)分别为96.3%(95%CI:92.9%,99.8%),86.4%(95%)在基于患者的分析中,CI:77.8%,94.9%,89.6%(95%CI:85.6%,93.6%)和93.2%(95%CI:84.1%,100%); 91.8%(95%CI:85.8%,97.8%),95.4%(95%CI:93.6%,97.1%),85.9%(95%CI:79.7%,92%)和97.4%(95%CI:95.9) %,99.1%),基于容器的分析; 86.2%(95%CI:81.8%,90.6%),96.5%(95%CI:95.2%,98%),79.9%(95%CI:75.3%,84.6%)和97.8%(95%CI:96.7) %,99%),分别基于基于细分的分析。 320层冠状动脉CT血管造影术的平均有效剂量为10.5 mSv(95%CI:6.1,14.8 mSv)。 320层冠状动脉CT血管造影的诊断价值不受不同心率和钙评分的影响(p> 0.05)。该分析表明320层冠状动脉CT血管造影对冠心病患病率高的患者具有较高的诊断价值。相对较高的辐射剂量主要是由于包括高心率患者并且未使用先进的降低剂量技术,因此,应实施进一步的剂量节省策略以最大程度地减少最终的辐射剂量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号