A simultaneous HPLC determination of six sulfonamides (SAs) [sulfadiazine (SDA), sulfadimidine (SDD), sulfamonomethoxine (SMM), sulfamethoxazole (SMX), sulfadimethoxine (SDM), and sulfaquinoxaline (SQ)] in meat (chicken, beef, and pork) is presented. The sample preparation is carried out by normal-phase matrix solid-phase dispersion (MPSD) with an aqueous ethanol solution. The HPLC determination is performed using a Mightysil RP-4 GP column and an isocratic mobile phase of 2% (v/v) acetic acid solution (pH 2.7, in water)-ethanol (75:25, v/v) with a photodiode array detector. Average recoveries spiked at 0.05-0.5 ppm for each drug are higher than 85% with standard deviations within 10%. In all the processes, no toxic/harmful solvents are used at all.
机译:HPLC同时测定肉类(鸡肉,牛肉和牛肉)中的六种磺酰胺(SA)[磺胺嘧啶(SDA),磺胺二甲胺(SDD),磺胺单甲恶碱(SMM),磺胺甲恶唑(SMX),磺胺二甲恶碱(SDM)和磺胺喹喔啉(SQ)猪肉)。样品制备是通过正相/固相基质固相分散体(MPSD)与乙醇水溶液进行的。使用Mightysil RP-4 GP色谱柱和2%(v / v)乙酸溶液(pH 2.7,在水中)-乙醇(75:25,v / v)的等度流动相和光电二极管进行HPLC测定阵列检测器。每种药物的0.05-0.5 ppm加标的平均回收率高于85%,标准偏差在10%以内。在所有过程中,完全不使用有毒/有害溶剂。