首页> 外文期刊>Journal of nuclear medicine technology >Use of a voxel phantom as a source and a second voxel phantom as a target to calculate effective doses in individuals exposed to patients treated with 131I.
【24h】

Use of a voxel phantom as a source and a second voxel phantom as a target to calculate effective doses in individuals exposed to patients treated with 131I.

机译:使用体素体模作为来源,使用第二个体素体模作为目标来计算暴露于131I治疗的患者的个体中的有效剂量。

获取原文
获取原文并翻译 | 示例
       

摘要

In this study, the Visual Monte Carlo radiation transport code and the female voxel phantom FAX were used to calculate organ and effective doses delivered by target-source irradiation geometries associated with radioiodine therapy treatments. METHODS: Specific situations were considered: when a patient was accompanied during hospitalization, when a patient was accompanied on return to his or her residence, and when a patient received daily care at home. RESULTS: This simulation study showed that, in the 3 situations considered, the total effective dose to an individual in normal contact with the patient was less than 0.85 mSv for up to 11.1 GBq (300 mCi) of administered activity. CONCLUSION: The results of this study suggest that for these patients receiving radioiodine therapy, radiation protection procedures after hospital discharge are unnecessary.
机译:在这项研究中,使用了视觉蒙特卡洛辐射传输代码和女性体素幻象FAX来计算与放射碘治疗相关的靶源辐射几何形状所传递的器官和有效剂量。方法:考虑了特定情况:住院期间有病人陪同,返回家园时有病人陪同,以及病人在家中接受日常护理。结果:这项模拟研究表明,在所考虑的3种情况下,对于与患者正常接触的个体,在最高11.1 GBq(300 mCi)的给药活性下,其总有效剂量小于0.85 mSv。结论:本研究结果表明,对于这些接受放射碘治疗的患者,出院后无需进行放射防护程序。