首页> 外文期刊>Journal of Pharmaceutical and Biomedical Analysis: An International Journal on All Drug-Related Topics in Pharmaceutical, Biomedical and Clinical Analysis >Development and validation of a high-performance liquid chromatography-mass spectrometry assay for methylxanthines and taurine in dietary supplements.
【24h】

Development and validation of a high-performance liquid chromatography-mass spectrometry assay for methylxanthines and taurine in dietary supplements.

机译:膳食补充剂中甲基黄嘌呤和牛磺酸的高效液相色谱-质谱分析方法的开发和验证。

获取原文
获取原文并翻译 | 示例
           

摘要

A procedure based on liquid chromatography-mass spectrometry (LC-MS) is described for determination of caffeine, theobromine, theophylline, taurine in different dietary supplements. After addition of tryptophan as internal standard, both solid and liquid specimens were extracted with 4ml of hexane/isopropanol (9:1). Chromatography was performed on a C(18) reversed-phase column using water/methanol/acetic acid (75:20:5, v/v/v) as a mobile phase. Analytes were determined in LC-MS single ion monitoring mode with atmospheric pressure ionization-electrospray (ESI) interface. The method was validated in the range 0.1-500 and 0.06-500mug/ml or mug/g for taurine and caffeine, respectively; 0.06-100mug/ml or mug/g for theobromine and theophylline. Mean recoveries ranged between 70.1 and 94.4% for different analytes. The quantification limits were 0.1mug/ml or mug/g for taurine and 0.06mug/ml or mug/g for methylxanthines either in liquid samples or in solid samples. The method was applied to the analysis of various dietary supplements containing methylxanthines and taurine. Energetic drinks contained amounts of taurine in the range of hundreds to thousands mug/ml and ten times lower amounts of caffeine. Conversely, herbal powders, tablets and capsules mainly contained mg amounts of caffeine per gram of product with the other two methylxanthines in the range of ten to hundred mug/g.
机译:描述了一种基于液相色谱-质谱(LC-MS)的方法,用于测定不同膳食补充剂中的咖啡因,可可碱,茶碱,牛磺酸。加入色氨酸作为内标后,用4ml己烷/异丙醇(9:1)提取固体和液体样品。使用水/甲醇/乙酸(75:20:5,v / v / v)作为流动相,在C(18)反相色谱柱上进行色谱分离。在具有大气压电离-电喷雾(ESI)接口的LC-MS单离子监测模式下测定分析物。牛磺酸和咖啡因的方法分别在0.1-500和0.06-500ug / ml或马克杯/ g范围内验证; 0.06-100马克杯/毫升或可可碱和茶碱/马克杯/克。不同分析物的平均回收率在70.1%至94.4%之间。液体样品或固体样品中牛磺酸的定量限为0.1杯/毫升或马克杯/克,甲基黄嘌呤为0.06杯/毫升或马克杯/克。该方法用于分析各种含有甲基黄嘌呤和牛磺酸的膳食补充剂。高能饮料中牛磺酸的含量在数百至数千杯/毫升之间,咖啡因含量低十倍。相反,草药粉,片剂和胶囊剂每克产品中主要含有的咖啡因含量为毫克,另外两种甲基黄嘌呤的含量为十至一百杯/克。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号