Aim The purpose of this study was to evaluate a commercial antimicrobial formulation, Byotrol G32, as a potential coating for impeding biofilm formation on medical devices such as urinary catheters. Methods and Results The antimicrobial activity of Byotrol G32 and its individual constituents has been tested on planktonic and biofilm cultures of uropathogenic bacteria. The Byotrol G32 formulation was superior with MICs ranging from 3gml1 to 15gml1 for planktonic cultures and 320 gml1 for biofilms. Furthermore, Byotrol G32 was able to remove established biofilms and act as an antibiofilm surface coating. Conclusions Byotrol G32 displays impressive antimicrobial activity both in suspension and as a coating. Pretreating medical devices with Byotrol G32 may significantly impede biofilm formation and prolong the lifetime of the device. Significance and Impact of the study Medical devices are indispensable in health care. They are, however, a predisposing factor in infection. This research has demonstrated that Byotrol G32 reduces bacterial growth and subsequent biofilm formation. Application of Byotrol G32 as a medical device coating could have a significant impact on the costs associated with device replacement and patient morbidity and mortality.
机译:目的这项研究的目的是评估一种商业抗菌制剂Byotrol G32,它是一种潜在的涂层,可阻止在医疗设备(如导尿管)上形成生物膜。方法和结果Byotrol G32及其各个成分的抗菌活性已在尿毒症细菌的浮游生物膜和生物膜培养物中进行了测试。 Byotrol G32配方具有优越的MIC,浮游培养的MIC在3gml1至15gml1之间,而生物膜的MIC在320 gml1之间。此外,Byotrol G32能够去除已建立的生物膜并充当抗生物膜表面涂层。结论Byotrol G32在悬浮液和涂层中均显示出令人印象深刻的抗菌活性。用Byotrol G32预处理医疗设备可能会严重阻碍生物膜的形成并延长设备的使用寿命。研究的意义和影响医疗设备在医疗保健中必不可少。但是,它们是感染的诱因。这项研究表明Byotrol G32可以减少细菌的生长和随后的生物膜形成。将Byotrol G32用作医疗设备涂层可能会对与设备更换以及患者发病率和死亡率相关的成本产生重大影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号