首页> 外文期刊>Journal of clinical laboratory analysis. >Falsely Elevated Glucose Concentrations in Peritoneal Dialysis Patients Using Icodextrin
【24h】

Falsely Elevated Glucose Concentrations in Peritoneal Dialysis Patients Using Icodextrin

机译:腹膜透析患者使用艾考曲汀的血糖浓度错误升高

获取原文
获取原文并翻译 | 示例
           

摘要

Background: Peritoneal dialysis (PD) is used as an alternative to hemodialysis in end-stage renal disease (ESRD). Icodextrin has been used as a hyperosmotic agent in PD. The aim of the study was to assess two different point-of-care testing (POCT) glucose strips, affected and not affected by icodextrin, with serum glucose concentrations of the patients using and not using icodextrin. Methods: Fifty-two chronic ambulatory peritoneal dialysis (CAPD) patients using icodextrin (Extraneal (R)) and 20 CAPD patients using another hyperosmotic fluid (Dianeal (R)) were included in the study. Duplicate capillary and serum glucose concentrations were measured with two different POCT glucose strips and central laboratory hexokinase method. Assay principles of glucose strips were based on glucose dehydrogenase-pyrroloquinoline quinone (GDH-PQQ) and a mutant variant of GDH (Mut Q-GDH). The results of both strips were compared with those of hexokinase method. Results: Regression equations between POCT and hexokinase methods in icodextrin group were y = 2.55x + 1.12 mmol/l and y = 1.057x + 0.16 mmol/l for the GDH-PQQ and Mut Q-GDH methods, respectively. The mean difference between the results of hexokinase and those of GDH-PQQ and Mut Q-GDH in icodextrin group was 3.41 +/- 1.56 and 0.72 +/- 0.64 mmol/l, respectively. However, the mean differences were found much lower in the control group; 0.64 mmol/l for GDH-PQQ and 0.52 mmol/l for Mut Q-GDH. Conclusion: Compared to GDH-PQQ, glucose strips of Mut Q-GDH correlated better with hexokinase method in PD patients using icodextrin.(C) 2015 Wiley Periodicals, Inc.
机译:背景:腹膜透析(PD)在终末期肾脏疾病(ESRD)中被用作血液透析的替代方法。 Icodextrin已被用作PD中的高渗药物。该研究的目的是评估两种受艾考糊精影响和未受艾考糊精影响的即时检测(POCT)葡萄糖条,使用和不使用艾考糊精的患者的血清葡萄糖浓度。方法:本研究包括52例使用艾考糊精(Extraneal(R))的慢性非卧床腹膜透析(CAPD)患者和20例使用另一种高渗液(Dianeal(R))的CAPD患者。使用两种不同的POCT葡萄糖试纸和中央实验室己糖激酶法测量毛细管和血清葡萄糖的重复浓度。葡萄糖条的测定原理基于葡萄糖脱氢酶-吡咯并喹啉醌(GDH-PQQ)和GDH的突变体(Mut Q-GDH)。将两个试纸的结果与己糖激酶法的结果进行比较。结果:艾考糊精组中POCT和己糖激酶方法之间的回归方程分别为GDH-PQQ和Mut Q-GDH方法的y = 2.55x + 1.12 mmol / l和y = 1.057x + 0.16 mmol / l。艾考糊精组己糖激酶结果与GDH-PQQ和Mut Q-GDH结果之间的平均差分别为3.41 +/- 1.56和0.72 +/- 0.64 mmol / l。然而,对照组的平均差异要低得多。 GDH-PQQ为0.64 mmol / l,Mut Q-GDH为0.52 mmol / l。结论:与艾克糊精联合使用的PD患者中,Mut Q-GDH的葡萄糖条带与己糖激酶法的相关性更好(C)2015 Wiley Periodicals,Inc.

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号