首页> 外文期刊>World journal of urology >New alternatives for laser vaporization of the prostate: experimental evaluation of a 980-, 1,318- and 1,470-nm diode laser device.
【24h】

New alternatives for laser vaporization of the prostate: experimental evaluation of a 980-, 1,318- and 1,470-nm diode laser device.

机译:前列腺激光汽化的新替代品:980、1318和1470 nm二极管激光设备的实验评估。

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE: Several diode laser systems were introduced in recent years for the minimal-invasive surgical therapy of benign prostate enlargement. We investigated the ablation capacities, hemostatic properties and extend of tissue necrosis of different diode lasers at wavelengths of 980, 1,318 and 1,470 nm and compared the results to the 120 W GreenLight HPS laser. METHODS: The laser devices were evaluated in an ex vivo model using isolated porcine kidneys. The weight difference of the porcine kidneys after 10 min of laser vaporization defined the amount of ablated tissue. Blood loss was measured in blood-perfused kidneys following laser vaporization. Histological examination was performed to assess the tissue effects. RESULTS: The side-firing 980 and 1,470 nm diode lasers displayed similar ablative capacities compared to the GreenLight HPS laser (n.s.). The 1,318-nm laser, equipped with a bare-ended fiber, reached a higher ablation rate compared to the other laser devices (each P < 0.05). A calculated 'output power efficiency per watt' revealed that the 1,318-nm laser with a bare-ended fiber reached the highest rate compared to the side-firing devices (each P < 0.0001). All three diode lasers showed superior hemostatic properties compared to the GreenLight HPS laser (each P < 0.01). The extend of morphological tissue necrosis was 4.62 mm (1,318 nm), 1.30 mm (1,470 nm), 4.18 mm (980 nm) and 0.84 mm (GreenLight HPS laser), respectively. CONCLUSION: The diode lasers offered similar ablative capacities and improved hemostatic properties compared to the 120 W GreenLight HPS laser in this experimental ex vivo setting. The higher tissue penetration of the diode lasers compared to the GreenLight HPS laser may explain improved hemostasis.
机译:目的:近年来引入了几种二极管激光系统,用于前列腺增生的微创手术治疗。我们研究了不同二极管激光在980、1,318和1,470 nm波长下的消融能力,止血性能和组织坏死的范围,并将结果与​​120 W GreenLight HPS激光器进行了比较。方法:使用离体猪肾脏在离体模型中评估激光设备。激光蒸发10分钟后猪肾脏的重量差异定义了消融组织的数量。在激光汽化后,对充满血液的肾脏测量失血量。进行组织学检查以评估组织效果。结果:与GreenLight HPS激光器(美国国家标准)相比,侧面发射980和1,470 nm二极管激光器显示出相似的烧蚀能力。与其他激光设备相比,配备了裸光纤的1,318 nm激光器的烧蚀率更高(每个P <0.05)。计算出的“每瓦输出功率效率”表明,与侧面发射装置相比,具有裸露光纤的1,318-nm激光器达到了最高的发射率(每个P <0.0001)。与GreenLight HPS激光器相比,所有三个二极管激光器均显示出优异的止血性能(每个P <0.01)。形态组织坏死的范围分别为4.62 mm(1,318 nm),1.30 mm(1,470 nm),4.18 mm(980 nm)和0.84 mm(GreenLight HPS激光)。结论:在此实验离体设置中,与120 W GreenLight HPS激光器相比,二极管激光器提供了相似的烧蚀能力并改善了止血性能。与GreenLight HPS激光器相比,二极管激光器具有更高的组织穿透力,可以解释止血效果的改善。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号