首页> 外文期刊>Lasers in Medical Science >Ex vivo and in vivo investigations of the novel 1,470 nm diode laser for potential treatment of benign prostatic enlargement
【24h】

Ex vivo and in vivo investigations of the novel 1,470 nm diode laser for potential treatment of benign prostatic enlargement

机译:新型1470 nm二极管激光器的离体和体内研究可潜在治疗良性前列腺肿大

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Perioperative haemorrhage is still the major complication of transurethral resection of the prostate (TURP) for benign enlargement of the prostate. Photoselective vaporisation of the prostate (PVP) with the potassium–titanyl–phosphate (KTP) laser has been shown to achieve instant tissue ablation with excellent haemostatic properties. Our aim was to determine the tissue removal capacity, coagulation and haemostatic property of the novel 1,470 nm diode laser, ex vivo and in vivo. We evaluated two prototype diode laser systems at 1,470 nm in an ex vivo, isolated, blood-perfused, porcine kidney model (n = 5; 10 W–50 W) and in an in vivo investigation of beagle prostate (n = 4; 100 W) to assess vaporisation capacities and coagulation properties at different generator settings. The diode laser evaluation was compared with an 80 W KTP laser in the porcine model. After the laser treatment we performed a histological examination to compare the depth of coagulation and vaporisation. The diode laser system (50 W) showed significantly lower (P < 0.0001) capacities for tissue removal than the 80 W KTP laser (0.96 mm ± 0.17 mm and 5.93 mm ± 0.25 mm, respectively, P < 0.0001), while coagulation zones were significantly (P < 0.001) larger in diode laser-treated kidneys (3,39 mm ± 0.93 mm and 1.27 mm ± 0.13 mm, respectively). In vivo, the diode laser displayed rapid ablation of prostatic tissue with no intraoperative haemorrhage. Histological examination revealed coagulation zones of 2.30 mm (±0.26) at 100 W in the diode laser-treated prostates.
机译:围手术期出血仍是前列腺良性扩大的经尿道前列腺电切术(TURP)的主要并发症。业已证明,使用磷酸钾-钛氧烷基-磷酸钾(KTP)激光对前列腺(PVP)进行光选择性汽化可实现具有优异止血性能的即时组织消融。我们的目标是确定离体和体内新型1470 nm二极管激光器的组织去除能力,凝血和止血性能。我们在离体,离体,血液灌流的猪肾脏模型(n = 5; 10 W–50 W)和比格犬前列腺的体内研究(n = 4; 100)中评估了两个在1,470 nm处的二极管激光原型系统W)以评估不同发生器设置下的蒸发能力和凝结特性。将二极管激光器的评估结果与猪模型中的80 W KTP激光器进行了比较。激光治疗后,我们进行了组织学检查,以比较凝结和汽化的深度。与80 W KTP激光(分别为0.96 mm±0.17 mm和5.93 mm±0.25 mm,P <0.0001)相比,二极管激光系统(50 W)表现出的组织清除能力明显低(P <0.0001)。二极管激光治疗的肾脏(分别为3.39毫米±0.93毫米和1.27毫米±0.13毫米)明显更大(P <0.001)。在体内,二极管激光器显示出前列腺组织的快速消融,而没有术中出血。组织学检查发现二极管激光治疗的前列腺在100 W时有2.30 mm(±0.26)的凝结区。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号