首页> 外文期刊>The Journal of arthroplasty >Periprosthetic Fractures of the Acetabulum During Cup Insertion: Posterior Column Stability is Crucial
【24h】

Periprosthetic Fractures of the Acetabulum During Cup Insertion: Posterior Column Stability is Crucial

机译:杯插入过程中髋臼骨周围骨折:后柱稳定性至关重要

获取原文
获取原文并翻译 | 示例
       

摘要

Periprosthetic hip fractures around acetabular components are rare with little information available to guide surgical management of these complex injuries. A retrospective review of intraoperative isolated acetabular periprosthetic fractures from three tertiary surgical units was done. A total of 32 patients were identified with 9 initially missed. Acetabular components were stable (type 1) in 11 patients with no failures; unstable (type 2) in 12 patients and treated with supplemental fixation. Non-union and displacement were correlated with absent posterior column plating. Missed fractures (type 3) had the highest reoperation rate. Anterior patterns all healed, whereas fractureswith posterior column instability had a 67% failure rate. Periprosthetic acetabular fracture can heal successfully with posterior column stability. Plating is mandatory for large posterior wall fragments to achieve osteointegration. (C) 2014 Elsevier Inc. All rights reserved.
机译:髋臼周围的假体周围髋部骨折很少见,很少有信息可指导这些复杂损伤的手术治疗。回顾性分析了来自三个三级外科手术单位的术中孤立的髋臼假体周围骨折。总共确定了32例患者,其中9例最初漏诊。 11例没有失败的髋臼组件稳定(1型);不稳定(2型)的12例患者,并接受了辅助固定治疗。骨不连和移位与后柱缺板相关。漏掉的骨折(3型)再次手术率最高。前部形态全部愈合,而后柱不稳定的骨折失败率为67%。假体周围髋臼骨折可成功治愈,并具有后柱稳定性。大型后壁碎片必须进行电镀以实现骨整合。 (C)2014 Elsevier Inc.保留所有权利。