首页> 外文期刊>Radiation Protection Dosimetry >DOSE EVALUATION FOR FOETAL COMPUTED TOMOGRAPHY WITH A 320-ROW UNIT IN WIDE-VOLUME MODE AND AN 80-ROW UNIT IN HELICAL SCANNING MODE: A PHANTOM STUDY
【24h】

DOSE EVALUATION FOR FOETAL COMPUTED TOMOGRAPHY WITH A 320-ROW UNIT IN WIDE-VOLUME MODE AND AN 80-ROW UNIT IN HELICAL SCANNING MODE: A PHANTOM STUDY

机译:宽体积模式下320行单元和螺旋扫描模式下80行单元的胎儿X线计算机断层摄影术的剂量评估

获取原文
获取原文并翻译 | 示例
           

摘要

The purpose of this study was to evaluate the maternal and foetal effective doses during foetal computed tomography (CT) and to compare the radiation dose, dose profile and image noise on 80-row CT in helical scanning mode and 320-row CT in wide-volume scanning mode. The radiation doses were measured using thermoluminescent dosemeters implanted at various organ sites of an anthropomorphic pregnant phantom. The foetal doses in the 320-row multi-detector CT (MDCT) and 80-row MDCT units were higher than the volume CT dose index (CTDI_(vol)). The dose profile in the 320-row MDCT overlapped in two places but showed no overlap in the 80-row MDCT. There were no significant differences in image noise between the two scanning modes. The foetal dose evaluation by CTDI_(vol) may underestimate the foetal radiation risk. When using the wide-volume mode, operators must take into account the number of scans and overlap between volumetric sections.
机译:这项研究的目的是评估胎儿计算机断层扫描(CT)期间的母体和胎儿有效剂量,并比较螺旋扫描模式下的80行CT和宽扫描模式下的320行CT的放射剂量,剂量分布和图像噪声音量扫描模式。使用在拟人化怀孕体模的各个器官部位植入的热致发光剂量计测量辐射剂量。 320行多探测器CT(MDCT)和80行MDCT单位中的胎儿剂量高于体积CT剂量指数(CTDI_(vol))。 320行MDCT中的剂量分布在两个地方重叠,但在80行MDCT中没有显示重叠。两种扫描模式之间的图像噪声没有显着差异。通过CTDI_(vol)评估胎儿剂量可能会低估胎儿辐射风险。当使用大容量模式时,操作员必须考虑扫描的次数和体积部分之间的重叠。

著录项

  • 来源
    《Radiation Protection Dosimetry》 |2016年第4期|523-530|共8页
  • 作者单位

    Department of Imaging, Nagoya Kyoritsu Hospital, 1-172, Hokke, Nakagawa-ku, Nagoya, Aichi 454-0933, Japan,Graduate School of Medicine, Tohoku University, 2-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi 980-8575, Japan;

    Department of Radiology, Toyota Memorial Hospital, Toyota 471-0821, Japan,Graduate School of Medicine, Tohoku University, 2-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi 980-8575, Japan;

    School of Health Sciences, Fujita Health University, Toyoake 470-1192, Japan;

    Department of Radiology, School of Medicine, Fujita Health University, Toyoake 470-1192, Japan;

    School of Health Sciences, Fujita Health University, Toyoake 470-1192, Japan;

    Graduate School of Medicine, Tohoku University, 2-1 Seiryo-machi, Aoba-ku, Sendai, Miyagi 980-8575, Japan;

  • 收录信息 美国《科学引文索引》(SCI);美国《化学文摘》(CA);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号