首页> 美国卫生研究院文献>The Scientific World Journal >Diagnostic Phase of Calcium Scoring Scan Applied as the Center of Acquisition Window of Coronary Computed Tomography Angiography Improves Image Quality in Minimal Acquisition Window Scan (Target CTA Mode) Using the Second Generation 320-Row CT
【2h】

Diagnostic Phase of Calcium Scoring Scan Applied as the Center of Acquisition Window of Coronary Computed Tomography Angiography Improves Image Quality in Minimal Acquisition Window Scan (Target CTA Mode) Using the Second Generation 320-Row CT

机译:钙计分扫描的诊断阶段被用作冠状计算机断层扫描血管造影的采集窗口中心使用第二代320排CT在最小采集窗口扫描(目标CTA模式)下提高了图像质量

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Objective. To compare the image quality of coronary computed tomography angiography (CCTA) acquired under two conditions: 75% fixed as the acquisition window center (Group 75%) and the diagnostic phase for calcium scoring scan as the center (CS; Group CS). Methods. 320-row cardiac CT with a minimal acquisition window (scanned using “Target CTA” mode) was performed on 81 patients. In Group 75% (n = 40), CS was obtained and reconstructed at 75% and the center of the CCTA acquisition window was set at 75%. In Group CS (n = 41), CS was obtained at 75% and the diagnostic phase showing minimal artifacts was applied as the center of the CCTA acquisition window. Image quality was evaluated using a four-point scale (4-excellent) and the mean scores were compared between groups. Results. The CCTA scan diagnostic phase occurred significantly earlier in CS (75.7 ± 3.2% vs. 73.6 ± 4.5% for Groups 75% and CS, resp., p = 0.013). The mean Group CS image quality score (3.58 ± 0.63) was also higher than that for Group 75% (3.19 ± 0.66, p < 0.0001). Conclusions. The image quality of CCTA in Target CTA mode was significantly better when the center of acquisition window is adjusted using CS.
机译:目的。为了比较在以下两种条件下采集的冠状动脉计算机断层血管造影术(CCTA)的图像质量:将75%固定为采集窗口中心(75%组)和将钙评分扫描的诊断阶段作为中心(CS; CS组)。方法。对81例患者进行了具有最小采集窗口(使用“ Target CTA”模式扫描)的320行心脏CT。在75%组(n = 40)中,获得CS并将其重构为75%,将CCTA采集窗口的中心设置为75%。在CS组(n = 41)中,CS的获得率为75%,显示最小伪像的诊断阶段被用作CCTA采集窗口的中心。使用四点量表(4-极好)评估图像质量,并比较各组之间的平均得分。结果。 CCTA扫描诊断阶段明显早于CS(75%组和CS组分别为75.7±3.2%和73.6±4.5%,p = 0.013)。组CS图像质量平均得分(3.58±0.63)也高于75%组(3.19±0.66,p <0.0001)。结论。当使用CS调整采集窗口的中心时,在目标CTA模式下CCTA的图像质量明显更好。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号