首页> 外文期刊>Plasma Science, IEEE Transactions on >Electrical Measurements for Nanosecond Repetitive Pulsed Discharges
【24h】

Electrical Measurements for Nanosecond Repetitive Pulsed Discharges

机译:纳秒级重复脉冲放电的电气测量

获取原文
获取原文并翻译 | 示例

摘要

In this paper, a device for accurate electrical measurements for nanosecond repetitive pulsed discharges (NRPDs) is presented. The experimental setup developed is based on an interelectrode system integrated in a transverse electromagnetic cell. This setup allows synchronizing the voltage and current measurements with a 4-GHz frequency bandwidth, corresponding to 250-ps pulse duration. A coaxial-shaped sharp metallic needle serves as a probe for current measurements. The needle probe is also the point electrode of a point-to-plane system used to generate discharges. The experimental setup was used to electrically characterize NRP corona and diffuse discharges, in negative polarity. Discharge current pulses with rise times less than 1 ns and amplitudes up to 120 mA were measured. The energy deposited by discharges was also determined.
机译:在本文中,提出了一种用于纳秒级重复脉冲放电(NRPD)的精确电测量的设备。开发的实验装置基于集成在横向电磁电池中的电极间系统。此设置允许将电压和电流测量与4 GHz频率带宽(相当于250 ps脉冲持续时间)同步。同轴的尖锐金属针用作电流测量的探针。针型探针也是用于产生放电的点对平面系统的点电极。实验设置用于负极性地表征NRP电晕和扩散放电。测量了上升时间小于1 ns且幅度高达120 mA的放电电流脉冲。还确定了由放电沉积的能量。