首页> 外文期刊>Journal of information and computational science >Research on Lightning Protection Simulation of High-speed Railway Catenary Based on ATP-EMTP
【24h】

Research on Lightning Protection Simulation of High-speed Railway Catenary Based on ATP-EMTP

机译:基于ATP-EMTP的高速铁路接触网防雷仿真研究

获取原文
获取原文并翻译 | 示例

摘要

Lightning activities have a serious impact on the safe and reliable operation of high-speed railway. In order to make a proper assessment to lightning current withstand capacity of overhead contact line equipment, according to the improved electrical geometric model, the sites of contact netease by lightning were analyzed firstly, then based on the ATP-EMTP software, lightning catenary model was established, and the lightning resisting levels of overhead contact line equipment under different influencing factors were simulated. The results show that the catenary pillar, AF line and T line are highly vulnerable to lightning hazards. When lightning pillar, the lightning resisting level was under 7.1 kA. When lightning suspension wire, the lightning resisting level was under 2.5 kA. The level of lighting resistance can be enhanced when PW line was set up, but the levels of overhead contact line equipment will reduce after considering the power frequency voltage.
机译:闪电活动严重影响了高速铁路的安全可靠运行。为了对架空接触线设备的雷电承受能力做出适当的评估,根据改进的电气几何模型,首先分析了雷电接触网点的位置,然后基于ATP-EMTP软件,建立了雷电接触网模型。建立了高架接触线设备在不同影响因素下的抗雷等级。结果表明,悬链线,AF线和T线极易遭受雷击危害。当使用雷电支柱时,其抗雷水平低于7.1 kA。当使用避雷线时,其抗雷水平低于2.5 kA。设置PW线可以提高耐光性,但考虑工频电压后,架空接触线设备的水平会降低。