An approach to the design and fabrication of a mass flow meter of a fluid using heat transfer technology is presented. The method uses the application of a simple matched pair of transistors as the flow transducer and compares the results with another flow transducer using a platinum resistance temperature detector. The effect of the temperature of the fluid is eliminated using the bridge circuit with the reference temperature probe placed in the static reference bath within the flow meter.
机译:提出了一种使用传热技术来设计和制造流体质量流量计的方法。该方法使用一对简单匹配的晶体管作为流量传感器,并将结果与​​另一个使用铂电阻温度检测器的流量传感器进行比较。使用桥式电路将参考温度探头放置在流量计的静态参考槽中,可以消除流体温度的影响。