The license for Kori-1, the first commercial reactor in Busan, Korea, was terminated in June 2017; therefore, preparations are being made for its decommissioning. Because the radioactivity of Bio-shield varies greatly throughout the structure, the doses received by the workers depend on the location, order, and duration of dismantling operations. Thus, a model for evaluating the worker external dose during the dismantling of the Kori-1 bio-shield was developed, and work scenarios for dose assessment were designed. The Dose evaluation code VISIPLAN was used for dose assessment. The dose rate around the bio-shield was evaluated and the level of exposure to the operator was evaluated according to the work scenario. The maximum annual external dose was calculated as 746.86?mSv for a diamond wire saw operator under dry cutting conditions, indicating that appropriate protective measures, such as changing dismantling sequence, remote monitoring, shield installation, and adjustment of work team are necessary for the safe dismantling of the bio-shield. Through these protective measures, it was found that the worker's dose could be below the dose limit.
机译:Kori-1的许可,韩国釜山的第一个商业反应堆,于2017年6月终止;因此,正在退役的准备工作。由于生物屏蔽的放射性在整个结构中变化很大,因此由工人接收的剂量取决于拆除操作的位置,顺序和持续时间。因此,开发了一种用于评估Wori-1生物屏蔽的拆卸过程中的工人外部剂量的模型,设计了剂量评估的工作场景。剂量评估代码Visiplan用于剂量评估。评估生物屏蔽周围的剂量率,并根据工作场景评估对操作者的暴露水平。最大年度外部剂量计算为746.86?MSV在干切削条件下为金刚石线锯操作员进行钻石锯操作员,表明安全的适当保护措施,如改变拆卸序列,远程监控,屏蔽安装以及工作团队的调整是必要的拆除生物屏蔽。通过这些保护措施,发现工人的剂量可以低于剂量限制。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号