Objective To retrospectively analyze carotid ultrasonography detection results in patients with unilateral anterior circulation acute ischemic stroke, and to observe the influence of atherosclerotic plaque fibrous cap integrity on plaque stability. Methods In the long axis and the short axis of color Doppler ultrasonograpy, carotid artery wall, atherosclerotic plaques and the integrity of fibrous cap, as well as the number of plaques with low, medium and strong echo in unilateral carotid artery were observed and recorded, so as to judge the hemodynamic situation of stenosis artery. Results A total of 215 plaques were found in 86 patients, among whom 77 patients with incomplete fibrous cap, 72 cases with low echo plaques and 5 cases with medium echo plaques (χ2 = 37.703, P = 0.000). There were 46 cases with incomplete fibrous cap in the affected side and 31 cases with incomplete fibrous cap in the uninjured side (χ2 = 5.291, P = 0.021); 56 cases with low echo plaques in affected side and 44 cases with low echo plaques in uninjured side (χ2 = 0.168, P = 0.682). Fifteen cases presented carotid artery stenosis caused by low echo plaques located in initial part of internal carotid artery (10 cases), carotid bifurcation (4 cases) and external carotid artery (1 case). There was significant difference (χ2 = 3.900, P = 0.048) between carotid bifurcation (8.16%, 4/49) and initial part of internal carotid artery (27.03%, 10/37). Conclusions The relationship between atherosclerotic plaque fibrous cap integrity and stroke is close. Plaques with incomplete fibrous cap are mainly low echo plaques. Therefore, ultrasonic evaluation of plaque echo and fibrous cap integrity can judge the stability of plaque. Besides, it is more significant to examine fibrous cap integrity than simply assess plaque echo features clinically. doi:10.3969/j.issn.1672-6731.2014.02.003.
机译:目的回顾性分析单侧前循环急性缺血性卒中患者的颈动脉超声检查结果,观察动脉粥样硬化斑块纤维帽完整性对斑块稳定性的影响。方法观察并记录彩色多普勒超声长轴和短轴,颈动脉壁,动脉粥样硬化斑块,纤维帽的完整性以及单侧颈动脉回声低,中,强回声的斑块数量,从而判断狭窄动脉的血流动力学状况。结果86例患者中共发现215个斑块,其中77例纤维帽不完整,72例低回声斑块,5例中度回声斑块(χ2= 37.703,P = 0.000)。受累侧有46例纤维帽不完整,未受损伤侧31例纤维帽不完整(χ2= 5.291,P = 0.021);受累侧56例低回声斑,未损伤侧44例低回声斑(χ2= 0.168,P = 0.682)。 15例因颈内动脉起始部分低回声斑块引起的颈动脉狭窄(10例),颈动脉分叉(4例)和颈外动脉(1例)。颈内分叉(8.16%,4/49)与颈内动脉初始部分之间有显着差异(χ2= 3.900,P = 0.048)(27.03%,10/37)。结论动脉粥样硬化斑块纤维帽的完整性与卒中的关系密切。纤维帽不完整的斑块主要是低回声斑块。因此,超声评估斑块回声和纤维帽完整性可以判断斑块的稳定性。此外,检查纤维帽的完整性比简单地在临床上评估斑块回声特征更为重要。 doi:10.3969 / j.issn.1672-6731.2014.02.003。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号