摘要

Reported herein is the development of an analytical method for the detection of four oxidative stress biomarkers in wastewater using ultra-high-performance liquid chromatography coupled with tandem mass spectrometry (UHPLC-MS/MS) and solid phase extraction (SPE). The following four biomarkers of oxidative stress and lipid peroxidation have been investigated: hydroxynonenal–mercapturic acid (HNE-MA), 8-iso-prostglandin F2beta (8-iso-PGF2β), 8-nitroguanine (8-NO2Gua) and 8-hydroxy-2-deoxyguanosine (8-OHdG). The method showed very good performance: accuracy (> 87%), precision (> 90%), method quantification limits (1.3–3.0 ng L−1) and biomarker stability in wastewater in the case of HNE-MA, 8-OHdG and 8-iso-PGF2β. In contrast, 8-NO2Gua was found to be less stable in wastewater, which affected its method performance: accuracy (> 63%), precision (> 91%) and method quantification limits (85.3 ng L−1). Application of the developed method resulted in, for the first time, HNE-MA being successfully observed and quantified within wastewater over a study period of a week (displayed average daily loads per capita of 48.9 ± 4.1 mg/1000/people/day). 8-iso-PGF2β was detected with good intensity but could not be quantified due to co-elution with other isomers. 8-OHdG was detected, albeit at < MQL. This study demonstrates the potential for expanding on the possible endogenous biomarkers of health used in urban water fingerprinting to aid in measuring health in near-real time on a community-wide scale.
机译:本文报道了一种使用超高效液相色谱-串联质谱(UHPLC-MS / MS)和固相萃取(SPE)检测废水中四种氧化应激生物标志物的分析方法的开发。研究了以下四种氧化应激和脂质过氧化的生物标记:羟基壬烯-巯基酸(HNE-MA),8-异前列腺素F2beta(8-iso-PGF2β),8-硝基鸟嘌呤(8-NO2Gua)和8-羟基-2-脱氧鸟苷(8-OHdG)。该方法表现出非常好的性能:HNE情况下,该方法的准确度(> 87%),精度(> 90%),方法定量限(1.3-3.0ng L -1 )和废水中生物标志物的稳定性-MA,8-OHdG和8-iso-PGF2β。相反,发现8-NO2Gua在废水中不稳定,影响了其方法性能:准确度(> 63%),精密度(> 91%)和方法定量限(85.3ngL -1 )。在一周的研究期间内,首次成功应用所开发的方法成功地对废水中的HNE-MA进行了观察和定量(显示的人均日负荷为48.9±4.1 mg / 1000 /人/天)。检测到的8-iso-PGF2β具有良好的强度,但由于与其他异构体的共洗脱而无法定量。检测到8-OHdG,尽管

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号